Code :
  • Code: E001 0001
  • Description: Abnormal high temperature of Fixing Assembly (caused by Sub Thermistor)
  • Causes: It was detected that the temperature of the Sub Thermistor of the Fixing Assembly was abnormally high.
  • Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E003 0000
  • Description: Abnormal low temperature of Fixing Assembly
  • Causes: It was detected that the temperature of the Fixing Assembly was abnormally low.
  • Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E003 0001
  • Description: Abnormal low temperature of Fixing Assembly (caused by Sub Thermistor)
  • Causes: It was detected that the temperature of the Sub Thermistor of the Fixing Assembly was abnormally low.
  • Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E004 0000
  • Description: Error in fixing power supply drive circuit
  • Causes: The zero cross signal was not detected for the specified period of time or more.
  • Remedy: 1. Check the connector connection between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
  • Code: E012 0000
  • Description: Revolution of the ITB Motor did not reach the specified value
  • Causes: The cycle of the ITB Motor speed detection signal did not become the specified cycle since the ITB Motor started to be driven.
  • Remedy: 1. Check the connector between the ITB Motor and the DC Controller PCB. 2. Replace the ITB Motor. 3. Replace the DC Controller PCB.
  • Code: E012 0001
  • Description: Revolution of the ITB Motor was out of the specified range
  • Causes: After the cycle of the ITB Motor speed detection signal became the specified cycle once, it deviated from the specified cycle.
  • Remedy: 1. Check the connector between the ITB Motor and the DC Controller PCB. 2. Replace the ITB Motor. 3. Replace the DC Controller PCB.
  • Code: E014 0000
  • Description: Error in startup of Fixing Motor
  • Causes: Revolution of the Fixing Motor did not reach the specified value.
  • Remedy: 1. Check the connector between the ITB Motor and the DC Controller PCB. 2. Replace the ITB Motor. 3. Replace the DC Controller PCB.
  • Code: E014 0001
  • Description: Revolution of the Fixing Motor was out of the specified range
  • Causes: After the cycle of the Fixing Motor speed detection signal became the specified cycle once, it deviated from the specified cycle.
  • Remedy: 1. Check the connector between the ITB Motor and the DC Controller PCB. 2. Replace the ITB Motor. 3. Replace the DC Controller PCB.