Code :
  • Code: E000 0000
  • Description: Error in the fixing assembly start-up
  • Causes: Insufficient temperature rise detected by thermistor even after applying bias to the heater
  • Remedy: 1.Check connectors of fixing assembly, DC controller PCB, fixing power supply unit, etc. 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
  • Code: E001 0000
  • Description: Abnormally high temperature detected in fixing assembly
  • Causes: Abnormally high temperature detected by main thermistor
  • Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCB
  • Code: E001 0001
  • Description: Abnormally high temperature detected in fixing assembly (sub thermistor triggered)
  • Causes: Abnormally high temperature detected by sub thermistor (sub thermistor triggered)
  • Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
  • Code: E003 0000
  • Description: Abnormally low temperature detected in fixing assembly
  • Causes: Temperature drop detected by main thermistor after attaining the target temperature
  • Remedy: 1.Check connectors of fixing assembly / DC controller PC 2.Replace fixing film/fixing power supply units 3.Replace DC controller PCBs
  • Code: E003 0001
  • Description: Abnormally low temperature detected in fixing assembly (sub thermistor triggered)
  • Causes: Temperature drop detected by sub thermistor after attaining the target temperature (sub thermistor triggered)
  • Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
  • Code: E004 0000
  • Description: Error in fixing power supply drive circuit.
  • Causes: Error in zero-cross signal detection for the pre-defined duration
  • Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing power supply units
  • Code: E012 0000
  • Description: Error in ITB motor startup
  • Causes: Error in attaining the target ITB motor rotation detected based on ITB motor speed detection signal after ITB motor is actuated.
  • Remedy: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
  • Code: E012 0001
  • Description: Error in ITB motor startup
  • Causes: Error in ITB motor rotation after attaining the target rotation detected based on ITB motor speed detection signal
  • Remedy: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs