Code: D7-nn-Error

Description: System error
Causes: System error
Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)

Code: D8-nn-Error

Description: System error
Causes: System error
Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)

Code: D9-nn-Error

Description: System error
Causes: System error
Remedy: - Turn OFF and then ON the main power. If the error persists, obtain the following information and contact the department in charge of quality management. - Output STATUS PRINT/ P-PRINT. - Collect Sublog - Collect information on conditions to reproduce the error - Obtain user's print data (binary data)

Code: E000-0000

Description: Fixing temperature rising error
Causes: Temperature of the Main Thermistor did not become the specified temperature although the specified time had passed.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit

Code: E001-0000

Description: Abnormally high fixing temperature 1
Causes: The Main Thermistor detected a temperature higher than the specified temperature.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.

Code: E001-0001

Description: Abnormally high fixing temperature 2
Causes: The Sub Thermistor 1 detected a temperature higher than the specified temperature.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.

Code: E001-0004

Description: Abnormally high fixing temperature 3
Causes: The Sub Thermistor 2 detected a temperature higher than the specified temperature.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.

Code: E003-0000

Description: Abnormally low fixing temperature detection 1
Causes: Temperature of the Main Thermistor was lower than the specified temperature when the heater was ON.
Remedy: 1. Check the drawer connector between the Fixing Assembly and the Fixing Power Supply Unit. 2. Replace the Fixing Assembly. 3. Replace the Fixing Power Supply Unit.