Causes: Error in rotation of the Developing disengagement Motor
Remedy: 1. Check the connection of the Developing disengagement Motor. 2. Replace the Developing disengagement Motor. 3. Replace the DC Controller PCB
Code: E020-0000
Description: Color Displacement Density Sensor error
Causes: Error in the Color Displacement Density Sensor
Remedy: 1. Check the connection of the Color Displacement Density Sensor. 2. Replace the Color Displacement Density Sensor. 3. Replace the DC Controller PCB
Code: E066-0000
Description: Environment Sensor error
Causes: Failure of the Environment Sensor was detected.
Remedy: 1. Check the connection of the Environment Sensor. 2. Replace the Environment Sensor. 3. Replace the DC Controller PCB
Code: E06F-0068
Description: EEPROM access error
Causes: A failure of the EEPROM is detected.
Remedy: 1. Turn OFF and then ON the power. 2. Replace the Main Controller PCB.
Code: E078-0001
Description: Primary transfer disengagement mechanism error
Causes: Failure of the primary transfer disengagement mechanism
Remedy: 1. Check that the ITB Unit is installed properly. 2. Check the connector between the Fixing Motor and the DC Controller PCB. 3. Replace the Fixing Motor. 4. Replace the DC Controller PCB
Code: E100-0000
Description: Yellow Laser Scanner error
Causes: Failure of the Laser Assembly in the Laser Scanner Unit (Yellow)
Remedy: 1. Check the connector of the Laser Scanner Unit. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB
Code: E100-0001
Description: Magenta Laser Scanner error
Causes: Failure of the Laser Assembly in the Laser Scanner Unit (Magenta)
Remedy: 1. Check the connector of the Laser Scanner Unit. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller PCB
Code: E100-0002
Description: Cyan Laser Scanner error
Causes: Failure of the Laser Assembly in the Laser Scanner Unit (Cyan)
Remedy: 1. Check the connector of the Laser Scanner Unit. 2. Replace the Laser Scanner Unit. 3. Replace the DC Controller P