Causes: If increasing temperature is not detected by main thermistor after current distribution to the heater is started. Cause Open circuit in the main thermistor, disconnection in the fixing heater, failure in DC controller PCB
Remedy: • - Check the connectors of fixing assembly, DC controller PCB, and fixing • power supply • assembly. • - Replace the fixing film unit • - Replace the fixing power unit • - Replace the DC controller PCB
Description: Abnormal high temperature in fixing assembly
Causes: If abnormal high temperature is detected by main thermistor. Cause Failure in sub thermistor, failure in DC controller PCB.
Remedy: • - Check the connectors of fixing assembly and DC controller PCB • - Replace the fixing film unit • - Replace the fixing power unit • - Replace the DC controller PCB
Description: Abnormal high temperature in fixing assembly
Causes: If abnormal high temperature is detected by sub thermistor (caused by sub thermistor). Cause Failure in sub thermistor, failure in DC controller PCB
Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
Description: Abnormal low temperature in fixing assembly
Causes: If decreasing temperature is detected after the main thermistor reaches a specified temperature. Cause Failure in fixing power unit, open circuit in the main thermistor, failure in DC controller PCB.
Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
Description: Abnormal low temperature in fixing assembly
Causes: If decreasing temperature is detected after the sub thermistor reaches a specified temperature. (cause by sub thermistor) Cause Failure in fixing power unit, open dircuit in the sub thermistor, failure in DC controller PCB.
Remedy: - Check the connectors of fixing assembly and DC controller PCB - Replace the fixing film unit - Replace the fixing power unit - Replace the DC controller PCB
Causes: The cycle of ITB motor speed detection signal does not move in the specified cycle after ITB motor drive is started. Cause Failure in ITB motor, failure in DC controller PCB
Remedy: - Check the connectors of ITB motor and DC controller PCB - Replace the ITB motor - Replace the DC controller PCB
Causes: If the ITB motor speed detection signal comes off the specified cycle after it turned once to the specified cycle. Cause Failure in ITB motor, failure in DC controller PCB.
Remedy: - Check the connectors of ITB motor and DC controller PCB - Replace the ITB motor - Replace the DC controller PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.