Code: E198

Description: Breakdown in DC controller memory
Causes: Breakdown in DC controller memory Cause Failure in DC controller PCB
Remedy: - Replace the DC controller PCB

Code: E602-0002

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Loading of Bootable ends in failure. Cause (Bootable is not stored or damaged.)
Remedy: - Reinstall the firmware. - Replace the Main Controller PCB.

Code: E602-0003

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Flash memory access error Cause An error occurred to the device or the hardware when the flash memory was being accessed during execution of bootrom.
Remedy: - Turn OFF and then ON the power. - Replace the Main Controller PCB.

Code: E602-0006

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Loading of SubBootable ends in failure. Cause (SubBootable is not stored or damaged.)
Remedy: - Reinstall the firmware. - Replace the Main Controller PCB.

Code: E602-0008

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Alternative block of flash memory is almost depleted.
Remedy: Perform the following procedure to replace the the Main Controller PCB and export/import user information. 1. Export user information from the flash memory of the old Main Controller PCB (before replacement). 2. Replace the Main Controller PCB. Import user information to the flash memory of the new Main Controller PCB (after replacement).

Code: E602-1102

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Error detection of file system (LBP7680Cx only)
Remedy: Execute the following procedures. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater. If E616-0001 occurs at restart after turning OFF and then ON the power, execute the following procedures. 1. Initialize MEAP area, and install MEAP application again. (Refer to the remedy for E616-0001.) 2. Download the /APL_CDS firmware again by Updater.

Code: E602-1112

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Device access error (LBP7680Cx only)
Remedy: Execute the following procedures. If E616- 0001 occurs after turning OFF and then ON the power (procedure 1), install MEAP application again by following the remedy for E616-0001 first. Then, execute the procedure 2. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.

Code: E602-1113

Description: E602-1102 to 1613 Only LBP7680Cx is supported.
Causes: Device access error (LBP7680Cx only)
Remedy: Execute the following procedures. If E616- 0001 occurs after turning OFF and then ON the power (procedure 1), install MEAP application again by following the remedy for E616-0001 first. Then, execute the procedure 2. 1. Turn OFF and then ON the power. 2. Download the /APL_CDS firmware again by Updater.