Description: Error in the fixing assembly start-up
Causes: Insufficient temperature rise detected by thermistor even after applying bias to the heater
Remedy: 1.Check connectors of fixing assembly, DC controller PCB, fixing power supply unit, etc. 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
Code: E001 0000
Description: Abnormally high temperature detected in fixing assembly
Causes: Abnormally high temperature detected by main thermistor
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCB
Code: E001 0001
Description: Abnormally high temperature detected in fixing assembly (sub thermistor triggered)
Causes: Abnormally high temperature detected by sub thermistor (sub thermistor triggered)
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
Code: E003 0000
Description: Abnormally low temperature detected in fixing assembly
Causes: Temperature drop detected by main thermistor after attaining the target temperature
Remedy: 1.Check connectors of fixing assembly / DC controller PC 2.Replace fixing film/fixing power supply units 3.Replace DC controller PCBs
Code: E003 0001
Description: Abnormally low temperature detected in fixing assembly (sub thermistor triggered)
Causes: Temperature drop detected by sub thermistor after attaining the target temperature (sub thermistor triggered)
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing film units 3.Replace fixing power supply units 4.Replace DC controller PCBs
Code: E004 0000
Description: Error in fixing power supply drive circuit.
Causes: Error in zero-cross signal detection for the pre-defined duration
Remedy: 1.Check connectors of fixing assembly / DC controller PCB 2.Replace fixing power supply units
Code: E012 0000
Description: Error in ITB motor startup
Causes: Error in attaining the target ITB motor rotation detected based on ITB motor speed detection signal after ITB motor is actuated.
Remedy: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
Code: E012 0001
Description: Error in ITB motor startup
Causes: Error in ITB motor rotation after attaining the target rotation detected based on ITB motor speed detection signal
Remedy: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs