Causes: Error in attaining the target fixing motor rotation detected based on fixing motor speed detection signal after fixing motor is actuated.
Remedy: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
Code: E014 0001
Description: Error in fixing motor startup
Causes: Error in fixing motor rotation after attaining the target rotation detected based on fixing motor speed detection signal.
Remedy: 1.Check connectors of ITB motor / DC controller PCB 2.Replace ITB motors 3.Replace DC controller PCBs
Code: E015 0001
Description: Error in developing roller contact
Causes: Failed to detect changes in developing home position sensor signals within the pre-defined time after actuating main motor to control the developing roller contact.
Remedy: 1.Check connectors of developing home position sensor, main motor and DC controller PCB. 2.Replace developing home position sensors 3.Replace main motors 4.Replace DC controller PCBs
Code: E020 0000
Description: Error in density sensor
Causes: Failed to receive sufficient light to detect image density
Remedy: 1.Check DC controller PCB onnectors. 2.Replace ITB units 3.Replace DC controller PCBs 4.Replace toner cartridges
Code: E021 1003
Description: Error in developing motor
Causes: Cause of developing motor rotation error: problem in developing motor / DC controller PCB
Remedy: 1.Check connectors of developing motor and DC controller PCB. 2.Replace developing motor 3.Replace DC controller PCB
Code: E021 2003
Description: Error in developing motor
Causes: Error in attaining the target developing motor rotation detected based on developing motor speed detection signal after developing motor is actuated.
Remedy: 1.Check connectors of developing motor and DC controller PCB. 2.Replace developing motor 3.Replace DC controller PCBs
Code: E024 0000
Description: Error in toner level sensor
Causes: Abnormal output of toner level sensor (Yellow)
Remedy: 1.Replace toner cartridges 2.Replace high-voltage power supply PCBs 3.Replace DC controller PCBs
Code: E024 0001
Description: Error in toner level sensor
Causes: Abnormal output of toner level sensor (Magenta)
Remedy: 1.Replace toner cartridges 2.Replace high-voltage power supply PCBs 3.Replace DC controller PCBs