Remedy: Check the memory capacity of ROM mounted on the Main Controller.
Code: E604 0001
Description: Memory error
Causes: Failed to allocate the memory required to start PDL.
Remedy: Check the installed memory, remove and then install the memory, and replace the memory.
Code: E616 0001
Description: MEAP application is lost.
Causes: MEAP application is lost.
Remedy: Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main power. * The setting is switched to the following after reboot. Initial screen setting: Native MEAP authentication: Off USB-Host setting: Native CDS-related: Off
Code: E616 0002
Description: System error
Causes: System error
Remedy: Execute Setup > Initialize Panel Setting to initialize NVRAM.
Code: E730 100A
Description: System error
Causes: System error
Remedy: 1. Turn OFF and then ON the main power. 2. Replace the Main Controller PCB.
Code: E730 C000
Description: An error, such as failure in memory retrieval at initialization, occurred.
Causes: An error, such as failure in memory retrieval at initialization, occurred.
Remedy: Turning OFF and then ON the main power executes auto recovery.
Code: E730 C001
Description: An error occurred when accessing the controller.
Causes: An error occurred when accessing the controller.
Remedy: Turning OFF and then ON the main power executes auto recovery.
Code: E730 D000
Description: An error, such as failure in memory retrieval at initialization, occurred.
Causes: An error, such as failure in memory retrieval at initialization, occurred
Remedy: Turning OFF and then ON the main power executes auto recovery.