Remedy: 1. Install the set of the controller firmware. 2. Replace the Main Controller PCB.
Code: E602 0008
Description: Memory area in the flash is depleted.
Causes: Remaining memory area in the flash is small.
Remedy: * Turning OFF and then ON the main power stops the error code to be displayed, but the continuous use causes the memory area in the flash to be completely lost or causes symptoms as such as machine freeze. 1. Turning OFF and then ON the main power stops the error code to be displayed. 2. Export user information. 3. Replace the Main Controller PCB. 4. Import user information.
Code: E602 0009
Description: MEAP cannot be started.
Causes: MEAP cannot be started due to an error caused by invalid power down.
Remedy: Select Function.gr > MEAP > MEAP FUNCTION = ON, and turn OFF and then ON the main power. * Since the installed MEAP application and its management information are all cleared after reboot, MEAP needs to be reinstalled.
Code: E602 1102
Description: File system could not be initialized normally (MEAP-related).
Causes: File system could not be initialized normally (MEAP-related).
Remedy: Turning OFF and then ON the main power executes auto recovery. Since E616-0001 may be displayed in some cases, execute the remedy for E616-0001. * When this error occurs, the firmware downloaded by the CDS Updator will be lost.