Description: PCB I2C bus error (support number : 4801)
Causes: Abnormal check sum value of the ink agitation timer or ink cleaning timer is detected, or accessing DA converter is disabled.
Remedy: 1 Reinstall the firmware. The problem is resolved Complete. The problem is not resolved Replace the MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: Memory acquisition disable error (support number : 4801)
Causes: Acquisition of OS memory pool packet is disabled.
Remedy: 1 Reinstall the firmware. The problem is resolved Complete. The problem is not resolved Replace the MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: Access cover open error at the cover locking (support number : 1214)
Causes: Cover open is detected when the access cover is being locked.
Remedy: 1 Close the access cover, and reboot. The problem is resolved Complete. The problem is not resolved Replace the MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Description: Left ink level abnormal detection error (support number : 4801)
Causes: The state that the longer ink level detection pin in the sub ink tank unit is OFF. In addition, the shorter ink level detection pin is ON is detected. (It occurs at cable connection failure. This state does not normally occur.)
Remedy: 1 Check the connection of the MAIN PCB UNIT. Proper connection Go to 2. Improper connection Connect the connector. The place to check the connection of the MAIN PCB UNIT 2 Check the connection of the left TANK PCB UNIT. Proper connection Replace the MAIN PCB UNIT. Improper connection Connect the connector. The place to check the connection of the left TANK PCB UNIT.
Description: Right ink level abnormal detection error (support number : 4801)
Causes: The state that the longer ink level detection pin in the sub ink tank unit is OFF. In addition, the shorter ink level detection pin is ON is detected. (It occurs at cable connection failure. This state does not normally occur.)
Remedy: 1 Check the connection of the left MAIN PCB UNIT. Proper connection Go to 2. Improper connection Connect the connector. The place to check the connection of the left MAIN PCB UNIT. 2 Check the connection of the right TANK PCB UNIT. Proper connection Replace the MAIN PCB UNIT. Improper connection Connect the connector. The place to check the connection of the right TANK PCB UNIT.
Description: Left and right ink level abnormal detection error (support number : 4801)
Causes: The state that the both left and right longer ink level detection pins in the sub ink tank units are OFF. In addition, the shorter ink level detection pins are ON is detected. (It occurs at cable connection failure. This state does not normally occur.)
Remedy: 1 Check the connection of the MAIN PCB UNIT. Proper connection Go to 2. Improper connection Connect the connector. The place to check the connection of the MAIN PCB UNIT. 2 Check the connection of the left TANK PCB UNIT. Proper connection Replace the MAIN PCB UNIT. Improper connection Connect the connector. The place to check the connection of the left and right TANK PCB UNIT.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.