Description: Carriage board I2C bus communication error (support number : 4801)
Causes: I2C writing and reading to ICs on the carriage board is failed.
Remedy: 1 Perform [DIAGNOSIS > CR_SYSTEM_CHECK] to check broken wires of FLEXIBLE CABLE UNIT. Without broken wires Replace CARRIAGE UNIT. With broken wires Replace FLEXIBLE CABLE UNIT.
Description: Abnormal temperature error by temperature and humidity sensor (support number : 8200) Memo : Remove the error in service mode after handling.
Causes: Abnormity is detect at reading temperature.
Remedy: 1 Check the cable connection of SENSOR, HUMIDITY. Proper connection Replace SENSOR, HUMIDITY. Improper connection Connect the cable.
Description: Abnormal humidity error by temperature and humidity sensor (support number : 8200) Memo : Remove the error in service mode after handling.
Causes: Abnormity is detected at reading humidity.
Remedy: 1 Check the cable connection of SENSOR, HUMIDITY. Proper connection Replace SENSOR, HUMIDITY. Improper connection Connect the cable.
Description: Mist fan error (support number : 4801)
Causes: Abnormity is detected at reading humidity.
Remedy: 1 Check the cable connection of MIST FAN. Proper connection Go to 2. Improper connection Connect the cable. 2 Replace the parts below. <24. model> MIST FAN DUCT UNIT 2 <44. model> MIST FAN DUCT UNIT 1, MIST FAN DUCT UNIT 2 <60. model> MIST FAN DUCT UNIT 2 x 2 The problem is resolved Complete. The problem is not resolved Replace MAIN PCB UNIT. (After replacement, perform PCB replacement mode and necessary adjustments.)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.