Description: Device abnormal completion
An abnormal signal from the Main Controller PCB to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0510
Description: Device timeout
An image synchronous signal from the Main Controller PCB to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0511
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0520
Description: Device timeout
An image synchronous signal from the Main Controller PCB to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0521
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0530
Description: Device timeout
An image synchronous signal from the Main Controller PCB to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0531
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).
Code: E315-0540
Description: Device timeout
An image synchronous signal from the Main Controller PCB to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power.
2. Check the connection of the Main Controller PCB (including the flat cable).
3. Replace the flat cable.
4. Replace the Main Controller PCB (PCB2).