Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance 4225 — Trang 24/31

Code: E711-0001

Description: UFDI communication error
Communication system error (reception time out error/ checksum error etc.)
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.

Code: E711-0002

Description: IPC communication error
Communication system error (packet error occurs without the request of initialization)
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.

Code: E713-0000

Description: Erroneous communication with finisher (retry error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB

Code: E713-0001

Description: Erroneous communication with finisher (transmission retry error)
The communication does not restart by the error retry after the communication failure with the finisher
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.

Code: E713-0002

Description: Erroneous communication with finisher (transmission data error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.

Code: E713-0004

Description: Erroneous communication with finisher (reception error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.

Code: E713-0010

Description: Erroneous communication with finisher (reception error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.

Code: E713-0011

Description: Erroneous communication with finisher (reception error)
The communication does not restart by the error retry after the communication failure with the finisher.
Remedy: 1. Check the cable. 2. Replace the DC Controller PCB (UN2). 3. Replace the Finisher Controller PCB.