Các lỗi thường gặp

Code :
  • Code: 713-0022-05
  • Description: Erroneous communication with finisher (reception data error)
  • Causes: The communication does not restart by the error retry after the communication failure with the finisher.
  • Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2) to the Finisher Controller PCB. (PCB1/ PCB101) - Finisher Controller PCB (PCB1/PCB101) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Finisher Controller PCB. 3.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 716-0000-05
  • Description: Erroneous communication with cassette pedestal
  • Causes: After the presence of a cassette pedestal has been detected, the communication fails to be normal for 5 sec.
  • Remedy: [Related parts] - Cassette Feeding Unit-AN1:Harness connecting from the DC Controller PCB (UN2/J325) to the Pedestal Controller PCB (UN101/J32) - High Capacity Cassette Feeding Unit-B1:Harness connecting from the DC Controller PCB (UN2/ J338) to the High-capacity Cassette Driver PCB (UN104/J31) - Pedestal Controller PCB (UN101)/High-capacity Cassette Driver PCB (UN104) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the Pedestal Controller PCB (UN101)/High-capacity Cassette Driver PCB (UN104). 3.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: 719-0001-00
  • Description: Error in Coin Vendor.
  • Causes: Error in starting of the CoinVendor - The Coin Vendor, which should have been connected before the power was turned OFF, is not connected when the power is turned ON.
  • Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
  • Code: 719-0002-00
  • Description: Error in Coin Vendor.
  • Causes: Error in IPC when CoinVendor is running. - In the case of disconnection of IPC or an error in which IPC communication failed to be recovered. - When disconnection of the pickup delivery signal is detected. - When illegal connection is detected (short-circuit with Tx and Rx of IPC)
  • Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
  • Code: 719-0003-00
  • Description: Error in Coin Vendor.
  • Causes: - In the case of communication error with the coin vendor while obtaining the unit price at start-up.
  • Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
  • Code: 719-0004-00
  • Description: Coin vendor error
  • Causes: The coin vendor was connected to a model that does not support the coin vendor
  • Remedy: 1. Disconnect the coin vendor
  • Code: 719-0031-00
  • Description: Error in serial communication at the start of the New Card Reader
  • Causes: Failure in communication with the serial New Card Reader at start-up.
  • Remedy: - Check if the cable of the serial New Card Reader is disconnected. - Take out the serial New Card Reader. - COPIER > Function > CLEAR > CARD - COPIER > Function > CLEAR > ERR
  • Code: 719-0032-00
  • Description: Error in serial communication at the start of the New Card Reader
  • Causes: Communication failed in the middle of the operation although communication with the serial New Card Reader was successful at start-up.
  • Remedy: - Check if the cable of the serial New Card Reader is disconnected.