Causes: When determine the location of the AC Driver PCB, location is not corresponding at the 100V/ 120V/230V.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J303) to the AC Driver PCB (UN30/J116) - AC Driver PCB (UN30) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the AC Driver PCB. 3.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: When the home position of the shutter is not detected
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J334) to the Fixing Film Shutter HP Sensor (S10/J109) - Harness connecting from the DC Controller PCB (UN2/J334) to the Fixing Film Shutter motor (M8/J2037) - Fixing Film Shutter HP Sensor (S10) - Fixing Film Shutter motor (M8) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Failure of Fixing Film Edge Cooling Fan (Rear) (FM1)
Causes: When the lock signal is detected for 15 sec while the fixing film edge cooling fan (rear) stops. * The same status is detected again after the retry operation.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J334) to the Fixing Film Cooling Fan (Rear) (FM1/J732) - Fixing Film Cooling Fan (Rear) (FM1) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Rotation error of Fixing Film Edge Cooling Fan (Rear) (FM1)
Causes: When the lock signal is detected for 15 sec while the fixing film cooling fan (rear) operates. * The same status is detected again after the retry operation.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J334) to the Fixing Film Cooling Fan (Rear) (FM1/J732) - Fixing Film Cooling Fan (Rear) (FM1) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Failure of Fixing Film Edge Cooling Fan (Front) (FM2)
Causes: When the lock signal is detected for 15 sec while the fixing film edge cooling fan (front) stops. * The same status is detected again after the retry operation.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J334) to the Fixing Film Cooling Fan (Front) (FM2/J733) - Fixing Film Cooling Fan (Front) (FM2) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Description: Rotation error of Fixing Film Edge Cooling Fan (Front) (FM2)
Causes: When the lock signal is detected for 15 sec while the fixing film edge cooling fan (front) operates. * The same status is detected again after the retry operation.
Remedy: [Related parts] - Harness connecting from the DC Controller PCB (UN2/J334) to the Fixing Film Cooling Fan (Front) (FM2/J733) - Fixing Film Cooling Fan (Front) (FM2) - DC Controller PCB (UN2) [Remedy] 1.Check/replace the related harness/cable, connector and parts. 2.Replace the DC Controller PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: It was detected that the Controller Fan was locked.
Remedy: [Related parts] R1.00 - Cable between the Main Controller PCB (UN25/J15) and the Controller Fan (FM12) - Controller Fan (FM12) - Main Controller PCB (UN25) [Remedy] Perform the following in the order while checking whether the error is cleared. - Check the connectors of the Controller Fan. - Visually check rotation of the Controller Fan. a. If it is not rotated, replace the Controller Fan. b. If it is rotated, replace the Main Controller PCB.
Causes: It was detected that the Controller Fan was locked.
Remedy: [Related parts] R1.00 - Cable between the Main Controller PCB and the Controller Fan - Controller Fan - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. - Check the connectors of the Controller Fan. - Visually check rotation of the Controller Fan. a. If it is not rotated, replace the Controller Fan. b. If it is rotated, replace the Main Controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.