Các lỗi thường gặp

Code :
  • Code: 614-FF01-00
  • Description: Flash PCB error
  • Causes: Flash error (Unidentified) (Initialization failed at startup or I/O error at startup) When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
  • Remedy: [Related parts] R1.00 - Flash PCB - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. Although the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to 4. 1. Check the related harness/cable and connector. 2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "0", and execute "HD-CHECK". Then, turn OFF and then ON the main power. 3. Obtain the necessary backup data by referring to the backup data list. [Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and "Appendix> Backup Data List" in the Service Manual. 4. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 5. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive. 6. Replace the Main Controller PCB.
  • Code: 614-FF11-00
  • Description: Flash PCB error
  • Causes: Flash error (Unidentified) (File could not be written in the Flash PCB after startup or I/O error after startup)
  • Remedy: [Related parts] R1.00 - Flash PCB - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. Although the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to 4. 1. Check the related harness/cable and connector. 2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "0", and execute "HD-CHECK". Then, turn OFF and then ON the main power. 3. Obtain the necessary backup data by referring to the backup data list. [Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and "Appendix> Backup Data List" in the Service Manual. 4. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 5. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive. 6. Replace the Main Controller PCB.
  • Code: 615-0001-00
  • Description: Error in self-diagnosis of the encryption module
  • Causes: An error was detected in self-diagnosis of the encryption library.
  • Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. - Reinstall the necessary application software and restore the backup data once the error is cleared. 1. After reinstalling the system software using SST or a USB memory, turn OFF and then ON the main power. 2. Obtain the necessary backup data by referring to the backup data list. 3. Enter safe mode using (2+8) startup, and execute [4] Clear/Format> [2] Flash Format (Flash format) using a USB memory. 4. After replacing the Flash PCB, reinstall the system software using SST or a USB memory. [Reference] For backup and restoration, refer to "Adjustment> Main Controller System" and "Appendix> Backup Data List" in the Service Manual.
  • Code: 674-0001-07
  • Description: Fax Board communication error
  • Causes: An error was detected for the specified number of times in communication with the Fax Board.
  • Remedy: [Related parts] R1.00 - Harness between the Fax Board and the Riser PCB - Fax Board - Riser PCB - Main Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 674-0002-07
  • Description: Fax Board communication error
  • Causes: An error was detected for the specified number of times in communication with the Fax Board.
  • Remedy: [Related parts] R1.00 - Harness between the Fax Board and the Riser PCB - Fax Board - Riser PCB - Main Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 674-0004-07
  • Description: Fax Board communication error
  • Causes: A communication error occurred when accessing the modem IC used for fax.
  • Remedy: [Related parts] R1.00 - Harness between the Fax Board and the Riser PCB - Fax Board - Riser PCB - Main Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 674-0008-07
  • Description: Fax Board communication error
  • Causes: A communication error occurred when accessing the port IC used for fax.
  • Remedy: [Related parts] R1.00 - Harness between the Fax Board and the Riser PCB - Fax Board - Riser PCB - Main Controller PCB [Remedy] Check/replace the related harness/cable, connector and parts.
  • Code: 674-0010-07
  • Description: Fax Board communication error
  • Causes: A communication error occurred when opening the Timer Device used for fax.
  • Remedy: Check/replace the Main Controller PCB