Description: Power Supply Cooling Fan (FM4) error
When detecting a failure of the Power Supply Cooling Fan (FM4).
Remedy: 1. Check the connector connection between the Power Supply Cooling Fan (FM4) and the AC Driver PCB (PCB4).
2. Replace the Power Supply Cooling Fan (FM4).
Description: Heat Exhaust Fan (Rear) (FM6) error
The lock signal was detected for 5.0 seconds while the Heat Exhaust Fan (Rear) (FM6) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Heat Exhaust Fan (Rear) (FM6) and the DC Controller PCB (PCB1).
2. Replace the Heat Exhaust Fan (Rear) (FM6).
3. Replace the DC Controller PCB (PCB1).
Description: Heat Exhaust Fan (Rear) (FM6) rotation error
The lock signal was not detected for 5.0 seconds while the Heat Exhaust Fan (Rear) (FM6) was being driven.
*The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Heat Exhaust Fan (Rear) (FM6) and the DC Controller PCB (PCB1).
2. Replace the Heat Exhaust Fan (Rear) (FM6).
3. Replace the DC Controller PCB (PCB1).
Description: Heat Exhaust Fan (Front) (FM5) error
The lock signal was detected for 5.0 seconds while the Heat Exhaust Fan (Front) (FM5) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Heat Exhaust Fan (Front) (FM5) and the DC Controller PCB (PCB1).
2. Replace the Heat Exhaust Fan (Front) (FM5).
3. Replace the DC Controller PCB (PCB1).
Description: Heat Exhaust Fan (Front) (FM5) rotation error
The lock signal was not detected for 5.0 seconds while the Heat Exhaust Fan (Front) (FM5) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Heat Exhaust Fan (Front) (FM5) and the DC Controller PCB (PCB1).
2. Replace the Heat Exhaust Fan (Front) (FM5).
3. Replace the DC Controller PCB (PCB1).
Description: Developing Cooling Fan (Front) (FM7) error
The lock signal was detected for 5.0 seconds while the Developing Cooling Fan (Front) (FM7) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Developing Cooling Fan (Front) (FM7) and the DC Controller PCB (PCB1).
2. Replace the Developing Cooling Fan (Front) (FM7).
3. Replace the DC Controller PCB (PCB1).
Description: Developing Cooling Fan (Front) (FM7) rotation error
The lock signal was not detected for 5.0 seconds while the Developing Cooling Fan (Front) (FM7) was being driven. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Developing Cooling Fan (Front) (FM7) and the DC Controller PCB (PCB1).
2. Replace the Developing Cooling Fan (Front) (FM7).
3. Replace the DC Controller PCB (PCB1).
Description: Developing Cooling Fan (Rear) (FM8) error
The lock signal was detected for 5.0 seconds while the Developing Cooling Fan (Rear) (FM8) was being stopped. *The same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection between the Developing Cooling Fan (Rear) (FM8) and the DC Controller PCB (PCB1).
2. Replace the Developing Cooling Fan (Rear) (FM8).
3. Replace the DC Controller PCB (PCB1).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.