Description: CIS Unit home position detection error
The CIS HP Sensor (PS24) did not detect the CIS Unit
Remedy: 1. Check the connection of the Flexible Cable between the Reader Controller PCB (PCB3) and the Main Controller PCB (PCB2).
2. Replace the Flexible Cable.
3. Replace the CIS HP Sensor (PS24).
4. Replace the Reader Motor (M10).
5. Replace the Reader Controller PCB (PCB3).
6. Replace the Main Controller PCB (PCB2).
Code: E202-0002
Description: CIS Unit home position detection error
The CIS Unit did not come off the CIS HP Sensor (PS24).
Remedy: 1. Check the connection of the Flexible Cable between the Reader Controller PCB (PCB3) and the Main Controller PCB (PCB2).
2. Replace the Flexible Cable.
3. Replace the CIS HP Sensor (PS24).
4. Replace the Reader Motor (M10).
5. Replace the Reader Controller PCB (PCB3).
6. Replace the Main Controller PCB (PCB2).
Code: E240-0000
Description: Controller communication error
A serial communication error was detected during normal operation.
Remedy: 1. Check the connector connection between the DC Controller PCB (PCB1) and the Main Controller PCB (PCB2).
2. Replace the DC Controller PCB (PCB1).
Code: E240-0001
Description: Controller communication error
A serial communication error was detected during printing.
Remedy: 1. Check the connector connection between the DC Controller PCB (PCB1) and the Main Controller PCB (PCB2).
2. Replace the DC Controller PCB (PCB1).
Code: E246
Description: System error
Remedy: Contact the service company office
Code: E247
Description: System error
Remedy: Contact the service company office
Code: E248-0000
Description: Reader backup data read error
The verification of the reader backup data failed to match.
Remedy: 1. Check the connector connection between the Reader Controller PCB (PCB3) and the Main Controller PCB (PCB2).
2. Replace the Reader Controller PCB (PCB3).
3. Replace the Main Controller PCB (PCB2).
Code: E261-0000
Description: Zero cross signal error
The zero cross signal was not detected for 500msec or longer while the relay turned to on.
*When the same status was detected again after executing an error retry.
Remedy: 1. Check the connector connection. (All connectors on the DC Controller PCB)
2. Replace the DC Controller PCB (PCB1).
3. Replace the AC Driver PCB (PCB4).