Description: Polygon Motor FG unlock error
Locked state was not detected within the specified period of time at start-up. (Power is not supplied/Polygon Motor signal error)
Remedy: 1. Check if the door is opened. Close the door. 2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35). DC Controller side: J471, J472, Laser Driver side: J5100, J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011 3. Replace the Laser Scanner Unit. 4. Replace the Laser Driver PCB (PCB35). 5. Replace the DC Controller PCB (PCB1).
Description: Polygon Motor FG unlock error
After the BD range was specified, lock was unlocked for 1 second or longer. (Power is not supplied/Polygon Motor signal error)
Remedy: 1. Check if the door is opened. Close the door. 2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35). DC Controller side: J471, J472, Laser Driver side: J5100, J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011 3. Replace the Laser Scanner Unit. 4. Replace the Laser Driver PCB (PCB35). 5. Replace the DC Controller PCB (PCB1).
Description: Polygon Motor FG unlock error
During the Polygon speed change, lock was unlocked for 1 second or longer. (Power is not supplied/Polygon Motor signal error)
Remedy: 1. Check if the door is opened. Close the door. 2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35). DC Controller side: J471, J472, Laser Driver side: J5100, J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011 3. Replace the Laser Scanner Unit. 4. Replace the Laser Driver PCB (PCB35). 5. Replace the DC Controller PCB (PCB1).
Description: Polygon Motor FG unlock error
Failed to get the Detailed Code (communication error, power supply error, PCB failure).
Remedy: 1. Check if the door is opened. Close the door. 2. Check the connector connection, open circuit, and the caught cable of the DC Controller PCB (PCB1) and the Laser Driver PCB (PCB35). DC Controller side: J471, J472, Laser Driver side: J5100, J5101, Relay Harness connection to Polygon Motor (M44) and BD Sensor: J3011 3. Replace the Laser Scanner Unit. 4. Replace the Laser Driver PCB (PCB35). 5. Replace the DC Controller PCB (PCB1).
Description: Laser Scanner Cooling Fan error.
The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Laser Scanner Cooling Fan (FM16) is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Laser Scanner Cooling Fan (FM16).
Description: Error in Main Driver PCB connection detection
Failed to establish a communication between the DC Controller PCB (PCB1) and the Main Driver PCB (PCB2).
Remedy: 1. Check the connection of the DC Controller PCB (PCB1) and the Main Driver PCB (PCB2). DC Controller side: J411, J412, Main Driver side: J125, J126 2. Check the Main Driver PCB (PCB2) power supply connection. Check the connection at the Main Driver side (J128) and the DC Controller side (J414), and check the voltage. 3. Replace the Main Driver PCB (PCB2). 4. Replace the DC Controller PCB (PCB1).
Description: Error in Feed Driver PCB connection detection
Failed to establish a communication between the DC Controller PCB (PCB1) and the Feed Driver Pub (PCB3).
Remedy: 1. Check the connection of the DC Controller PCB (PCB1) and the Feed Driver PCB (PCB3). DC Controller side: J421, Feed Driver side: J204 2. Check the connection of the Feed Driver PCB (PCB3) and the DC-DC Converter PCB. Check the connection at the Feed Driver side (J218) and the DC-DC Converter side (J9033). 3. Check the power supply of the Feed Driver PCB (PCB3). Check if appropriate voltages are applied to the Feed Driver side (12V to 1pin, 5V to 3pin, 3.3V to 4pin). -> If not, replace the DC-DC Converter PCB. 4. Replace the Feed Driver PCB (PCB3). 5. Replace the DC Controller PCB (PCB1).
Description: Error in Duplex Driver PCB connection detection
Failed to establish a communication between the DC Controller PCB (PCB1) and the Duplex Driver PCB (PCB4).
Remedy: 1. Check the connection between the DC Controller PCB (PCB1) and the Fixing Feed Drawer. DC Controller side: J431, J432, Fixing Feed Drawer (host machine side): J3002D Fixing Feed Drawer (Fixing Feed side): J3002L, Duplex Driver side: J300, J301 2. Check the connection of the Duplex Driver PCB (PCB4) and the DC-DC Converter PCB. Check the connection at the Duplex Driver side (J311) and the DC-DC Converter side (J9034). 3. Check the power supply of the Duplex Driver PCB (PCB4). Check if appropriate voltages are applied to the Duplex Driver side (12V to 1pin, 5V to 3pin, 3.3V to 4pin). -> If not, replace the DC-DC Converter PCB. 4. Replace the Duplex Driver PCB (PCB4). 5. Replace the DC Controller PCB (PCB1).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.