Causes: The coin vendor which was connected before turning OFF the main power was not connected at power-on.
Remedy: Check/replace the cable between the charging management equipment and the host machine. [Reference] When operating the machine without the charging management equipment, execute "COPIER> FUNCTION> CLEAR> ERR". (It is designed to generate an error to prevent the misuse by removing the charging management equipment.)
Code: 719-0002-00
Description: Coin vendor error
Causes: IPC error when the coin vendor is running - Open circuit of the IPC, or IPC communication could not be recovered. - Open circuit of the pickup/delivery signal cable was detected. - Invalid connection was detected.
Remedy: Check/replace the cable between the charging management equipment and the host machine. [Reference] When operating the machine without the charging management equipment, execute "COPIER> FUNCTION> CLEAR> ERR". (It is designed to generate an error to prevent the misuse by removing the charging management equipment.)
Code: 719-0003-00
Description: Coin vendor error
Causes: A communication error with the coin vendor was detected during unit price acquisition at startup.
Remedy: Check/replace the cable between the charging management equipment and the host machine. [Reference] When operating the machine without the charging management equipment, execute "COPIER> FUNCTION> CLEAR> ERR". (It is designed to generate an error to prevent the misuse by removing the charging management equipment.)
Code: 719-0031-00
Description: Card Reader communication error
Causes: Communication with the Card Reader could not be established at startup.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Check/replace the harness between the Card Reader and the Main Controller PCB (PWB1/ J4023 (white connector at the upper side). 2. Replace the Card Reader. [Reference] In the case of operating the device without the Card Reader which had been used, execute "COPIER> FUNCTION> CLEAR> CARD" after removing the Card Reader.
Code: 719-0032-00
Description: Card Reader communication error
Causes: Although communication with the Card Reader was available at startup, it became unavailable in the middle of it.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Check/replace the harness between the Card Reader and the Main Controller PCB (PWB1/ J4023 (white connector at the upper side). 2. Replace the Card Reader. [Reference] In the case of operating the device without the Card Reader which had been used, execute "COPIER> FUNCTION> CLEAR> CARD" after removing the Card Reader.
Code: 720-0001-05
Description: Error due to non-compatible Finisher
Causes: A finisher not supported by the host machine has been connected.
Remedy: Connect the finisher (STAPLE FIN-V1/BOOKLET FIN-V1) for this model.
Code: 720-0002-05
Description: Error due to non-compatible option deck
Causes: An option deck not supported by the host machine has been connected.
Remedy: Connect the option deck (POD DECK LITE-C1/PAPER DECK UNIT-E1) for this model.
Code: 720-0400-05
Description: Error due to non-compatible Finisher
Causes: A finisher not supported by the host machine has been connected.
Remedy: Connect the finisher (STAPLE FIN-V1/BOOKLET FIN-V1) for this model.