Causes: A communication error between the Reader Controller PCB and the Main Controller PCB 1 was detected at startup/recovery from sleep.
Remedy: [Related parts] - Harness between the Reader Controller PCB (UN1/J109) and the Main Controller PCB 2 (PWB02/J4031) (Unit of replacement: CABLE, INTERFACE) - Harnesses from the Relay PCB to the Reader Controller PCB 1. Relay PCB (UN7/J505) to Relay Connector (6P) (Unit of replacement: CABLE, SIGNAL) 2. Relay Connector (6P) to Reader Controller PCB (PCB1/J101) (Unit of replacement: CABLE, READER POWER SUPPLY) - Main Controller PCB 2 (PWB02) (Unit of replacement: MAIN CONTROLLER PCB ASS'Y, 2) - Main Controller PCB 1 (PWB01) (Unit of replacement: MAIN CONTROLLER PCB ASSEMBLY, 1) - Reader Controller PCB (UN1) (Unit of replacement: READER CONTROLLER PCB ASSEMBLY) - Relay PCB (UN7) (Unit of replacement: RELAY PCB ASSEMBLY) [Points to note at work] After performing the remedy, check that the copy image is output normally. [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the Reader Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> RSRAMRES
Causes: The Reader was detected with a printer model for the first time. Only the message "Turn OFF and then ON the power" is displayed on the screen instead of displaying an error code. The error log is recorded in "COPIER> DISPLAY> ERR".
Description: Communication error between the Main Controller PCB 1 and the DC Controller PCB
Causes: Unable to make communication between the Main Controller PCB 1 and the DC Controller PCB. (Communication error was detected during power distribution (while the power is ON).)
Remedy: 1. Turn OFF and then ON the power. 2. Check the cable connection (connector connection error/open circuit). - DC Controller PCB: J441, J442, Main Controller PCB 2: J21, J22 - Main Controller PCB 2: J2, Main Controller PCB 1: J1019 3. Replace the DC Controller PCB/Main Controller PCB 2/Main Controller PCB1.
Description: Communication error between the Main Controller PCB 1 and the DC Controller PCB
Causes: Error was detected in the signal from the DC Controller PCB to the Main Controller PCB 1. (Communication between the DC Controller PCB and the Main Controller PCB 1 is normal.)
Remedy: 1. Check the cable connection (connector connection error/open circuit). - DC Controller PCB: J441, J442, Main Controller PCB 2: J21, J22 - Main Controller PCB 2: J2, Main Controller PCB 1: J1019 2. Replace the DC Controller PCB/Main Controller PCB 2/Main Controller PCB1.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.