Description: Tray Lifter Motor (M8) error. The Tray HP Sensor (SR13) is not turned ON or OFF within the specified period of time although the Tray Lifter Motor (M8) is driven.
Remedy: 1. Connector disconnection/open circuit of the Tray HP Sensor (SR13). 2. Connector disconnection/open circuit of the Tray Lifter Motor (M8). 3. Failure of the Tray HP Sensor (SR13). 4. Failure of the Tray Lifter Motor (M8).
Code: E407-0002
Description: Tray Lifter Motor (M8) error. The Paper Surface Sensor (SR6) is not turned ON within the specified period of time although the Tray Lifter Motor (M8) is driven.
Remedy: 1. Connector disconnection/open circuit of the Paper Surface Sensor (SR6). 2. Connector disconnection/open circuit of the Tray Lifter Motor (M8). 3. Failure of the Paper Face Sensor (SR6). 4. Failure of the Tray Lifter Motor (M8).
Code: E413-0001
Description: DADF Disengagement Motor 1 (M6) error. The DADF Disengagement HP Sensor 1 (SR15) is not turned ON within the specified period of time although the DADF Disengagement Motor 1 (M6) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 1 (SR15). 2. Connector disconnection/open circuit of the Disengagement Motor 1 (M6). 3. Failure of the Disengagement HP Sensor 1 (SR15). 4. Failure of the Disengagement Motor 1 (M6). 5. Failure of the DADF Driver PCB (PCB1).
Code: E413-0002
Description: DADF Disengagement Motor 1 (M6) error. The DADF Disengagement HP Sensor 1 (SR15) is not turned OFF within the specified period of time although the DADF Disengagement Motor 1 (M6) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 1 (SR15). 2. Connector disconnection/open circuit of the Disengagement Motor 1 (M6). 3. Failure of the Disengagement HP Sensor 1 (SR15). 4. Failure of the Disengagement Motor 1 (M6). 5. Failure of the DADF Driver PCB (PCB1).
Code: E413-0011
Description: DADF Disengagement Motor 2 (M7) error. The DADF Disengagement HP Sensor 2 (SR16) is not turned ON within the specified period of time although the DADF Disengagement Motor 2 (M7) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 2 (SR16). 2. Connector disconnection/open circuit of the Disengagement Motor 2 (M7). 3. Failure of the Disengagement HP Sensor 2 (SR16). 4. Failure of the Disengagement Motor 2 (M7). 5. Failure of the DADF Driver PCB (PCB1).
Code: E413-0012
Description: DADF Disengagement Motor 2 (M7) error. The DADF Disengagement HP Sensor 2 (SR16) is not turned OFF within the specified period of time although the DADF Disengagement Motor 2 (M7) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 2 (SR16). 2. Connector disconnection/open circuit of the Disengagement Motor 2 (M7). 3. Failure of the Disengagement HP Sensor 2 (SR16). 4. Failure of the Disengagement Motor 2 (M7). 5. Failure of the DADF Driver PCB (PCB1).