Description: Rebooting due to SRAM corruption when executing a transmission job that secures disconnection of the power. In the case that reboot is repeated at recovery from power down because SRAM information is corrupted and the job information saved on SRAM cannot be read, the phenomenon that the communication is repeated occurs.
Remedy: Clear SRAM to erase the job that secures disconnection of the power.
Code: E677-0001
Description: Print server error. Exhaust Fan operation error on the print server is detected.
Remedy: 1. Check power supply to the Exhaust Fan. 2. Replace the Exhaust Fan.
Code: E677-0003
Description: Print server error. Error is detected at the configuration check performed at startup.
Remedy: Check the cable connection, reinstallation.
Code: E677-0004
Description: Print server error. CPU Fan operation error on the print server is detected.
Remedy: 1. Check power supply to the CPU Fan. 2. Replace the CPU Fan.
Code: E677-0010
Description: Print server error. Not proper print server is connected.
Remedy: Replace the print server with the proper one.
Code: E677-0080
Description: Print server error. Communication error at startup.
Remedy: Check the cable connection, reinstallation.
Code: E710-0001
Description: Printer IPC error. Error is detected by IPC communication IC of the printer engine at power ON.
Remedy: Disconnection of cable.
Code: E711-0001
Description: IPC communication error. Occurrence of error was set for 4 times or more for 1.5 seconds to the error register of the IPC Chip. Communication between the host machine and the Finisher was lost
Remedy: Check the Cable. 1. Check the cable connection. Check the connection between DCON side (J462) and Finisher Lattice side (J9043) Finisher Cable 2. Replace the DC Controller PCB