  • Code: E713-0040
  • Description: Finisher IPC communication error (serial error). Communication between the host machine and the Finisher was lost.
  • Remedy: 1. Check the cable connection of the Finisher. DC Controller side: J462, Finisher Lattice side: J9043 2. Replace the Finisher Controller PCB.
  • Code: E717-0001
  • Description: Communication error with the NE Controller. Error when the NE Controller is started. The NE Controller which was connected before turning OFF the power is not connected at power-on.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
  • Code: E717-0002
  • Description: Communication error with the NE Controller. IPC error at NE Controller operation. Open circuit of IPC, unable to recover the IPC communication.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
  • Code: E719-0001
  • Description: Error in coin manager. Error when the coin manager is started. The coin manager which was connected before turning OFF the power is not connected at power-on.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
  • Code: E719-0002
  • Description: Error in coin manager. IPC error at coin manager operation. Open circuit of IPC, unable to recover the IPC communication. When open circuit of the pickup/delivery signal cable is detected. Invalid connection is detected.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
  • Code: E719-0003
  • Description: Error in coin manager. Communication error with the coin manager occurs during unit price acquisition at startup.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
  • Code: E719-0011
  • Description: Error when the Card Reader is started. The Card Reader which was connected before turning OFF the power is not connected at power-on.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.
  • Code: E719-0012
  • Description: IPC error at Card Reader operation. Open circuit of IPC, unable to recover the IPC communication.
  • Remedy: Check the cable, and then go through the following to clear the error: Service Mode > COPIER > FUNCTION > CLEAR > ERR.