Description: Tray Lifter Motor (M8) error. The Tray HP Sensor (SR13) is not turned ON or OFF within the specified period of time although the Tray Lifter Motor (M8) is driven.
Remedy: 1. Connector disconnection/open circuit of the Tray HP Sensor (SR13). 2. Connector disconnection/open circuit of the Tray Lifter Motor (M8). 3. Failure of the Tray HP Sensor (SR13). 4. Failure of the Tray Lifter Motor (M8).
Description: Tray Lifter Motor (M8) error. The Paper Surface Sensor (SR6) is not turned ON within the specified period of time although the Tray Lifter Motor (M8) is driven.
Remedy: 1. Connector disconnection/open circuit of the Paper Surface Sensor (SR6). 2. Connector disconnection/open circuit of the Tray Lifter Motor (M8). 3. Failure of the Paper Face Sensor (SR6). 4. Failure of the Tray Lifter Motor (M8).
Description: DADF Disengagement Motor 1 (M6) error. The DADF Disengagement HP Sensor 1 (SR15) is not turned ON within the specified period of time although the DADF Disengagement Motor 1 (M6) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 1 (SR15). 2. Connector disconnection/open circuit of the Disengagement Motor 1 (M6). 3. Failure of the Disengagement HP Sensor 1 (SR15). 4. Failure of the Disengagement Motor 1 (M6). 5. Failure of the DADF Driver PCB (PCB1).
Description: DADF Disengagement Motor 1 (M6) error. The DADF Disengagement HP Sensor 1 (SR15) is not turned OFF within the specified period of time although the DADF Disengagement Motor 1 (M6) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 1 (SR15). 2. Connector disconnection/open circuit of the Disengagement Motor 1 (M6). 3. Failure of the Disengagement HP Sensor 1 (SR15). 4. Failure of the Disengagement Motor 1 (M6). 5. Failure of the DADF Driver PCB (PCB1).
Description: DADF Disengagement Motor 2 (M7) error. The DADF Disengagement HP Sensor 2 (SR16) is not turned ON within the specified period of time although the DADF Disengagement Motor 2 (M7) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 2 (SR16). 2. Connector disconnection/open circuit of the Disengagement Motor 2 (M7). 3. Failure of the Disengagement HP Sensor 2 (SR16). 4. Failure of the Disengagement Motor 2 (M7). 5. Failure of the DADF Driver PCB (PCB1).
Description: DADF Disengagement Motor 2 (M7) error. The DADF Disengagement HP Sensor 2 (SR16) is not turned OFF within the specified period of time although the DADF Disengagement Motor 2 (M7) is driven.
Remedy: 1. Connector disconnection/open circuit of the Disengagement HP Sensor 2 (SR16). 2. Connector disconnection/open circuit of the Disengagement Motor 2 (M7). 3. Failure of the Disengagement HP Sensor 2 (SR16). 4. Failure of the Disengagement Motor 2 (M7). 5. Failure of the DADF Driver PCB (PCB1).