Description: Fixing Power Supply error. Current fluctuation error.
Remedy: 1. Check the connection between the Main Driver PCB (PCB2) and the Fixing Power Supply PCB (PCB10). 2. Check the connection between the Fixing Power Supply PCB (PCB10) and the Heater Unit. 3. Replace the Fixing Assembly (Fixing Roller and Heater Unit). 4. Replace the Fixing Power Supply PCB (PCB10). 5. Replace the Main Driver PCB (PCB2).
Description: Developer Lower Cooling Fan error. The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Developer Lower Cooling Fan (FM30) is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Developer Lower Cooling Fan (FM30).
Description: Developer Upper Cooling Fan error. The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Developer Upper Cooling Fan (FM31) is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Developer Upper Cooling Fan (FM31).
Description: Duplex Driver Cooling Fan error. The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Duplex Driver Cooling Fan (FM41) is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Duplex Driver Cooling Fan (FM41).
Description: Primary Charging Air Supply Fan error. The Fan stop signal is detected for 5 seconds or longer and retry is failed 4 times in a row although the Primary Charging Air Supply Fan (FM2) is turned ON.
Remedy: 1. Check the connection of the Connector. 2. Replace the Primary Charging Air Supply Fan (FM2).
Description: Fixing Shutter Motor error. The Fixing Shutter HP Sensor (PS53) failed the detection at the Fixing Shutter operation.
Remedy: 1. Check the operation of the Fixing Shutter Gear (overload, etc.). 2. Check the operation of the Fixing Shutter Motor (M15) at the initialization operation of the Fixing Shutter. 3. Check the detection of the Fixing Shutter HP Sensor (PS53) (if the Sensor operates normally). 4. Check the drawer of the Fixing Assembly and the host machine. 5. Replace the Fixing Assembly. 6. Replace the Main Driver PCB (PCB2) (check the fuse (FU11)).