Các lỗi thường gặp

Code :
  • Code: E880-0005
  • Description: Controller Fan error. Error in the HDD Cooling Fan (FM) is detected.
  • Remedy: Connector disconnection, failure of Fan.
  • Code: E905-0001
  • Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Air Assist Swing Motor fails to return to the HP although a specified period of time has passed
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J04, J05 BoxDriver J51, J52, J57 2. Replace the Swing Motor (M3) and the Air Assist Fan (FM1, FM2, FM3). 3. Replace the Deck Lite Controller PCB. 4. Replace the BoxDriver PCB.
  • Code: E905-0002
  • Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Pickup Motor Cooling Fan is not locked
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
  • Code: E905-0003
  • Description: POD Deck Air Assist Fan error. [POD Deck Lite] When the Pickup Motor Cooling Fan is not unlocked
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J30 2. Replace the Motor Cooling Fan (FM4). 3. Replace the Deck Lite Controller PCB.
  • Code: E906-0001
  • Description: POD Deck Air Heater error. [POD Deck Lite] Air Heater high temperature error When 120 deg C or higher temperature is detected for 1 second consecutively
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
  • Code: E906-0002
  • Description: POD Deck Air Heater error. [POD Deck Lite] Air Heater low temperature error When the heater does not become Ready although a specified period of time has passed
  • Remedy: 1. Check connector disconnection/improper connection. => Disconnect and then connect the connector. Target connector: Deck Lite Controller J03, J05 BoxDriver J52, J54, J58, J59 2. Replace the Air Heater. 3. Replace the Deck Lite Controller PCB.
  • Code: E996-xxxx
  • Description: Timeout error. The DC Controller is not stopped. The Detailed Code varies according to the state transition of the software
  • Remedy: Turn OFF and then ON the main power.