Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C2020F — Trang 16/45

Code: E100-0001

Description: BD error
BD fails to be ready in 5 sec
Remedy: Scanner Motor movement error or BD signal error 1.COPIER > FUNCTION > PART-CHK > MTR; and move M01 When the Scanner Motor (M01) moves 2-1. Check the flexible cable/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 3-1. Replace the Laser Scanner Unit 4-1. Replace the DC Controller PCB (UN09) When the Scanner Motor (M01) does not move 2-2. Check the harness/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 3-2. Replace the Laser Scanner Unit 4-2. Replace the DC Controller PCB (UN09)

Code: E100-0002

Description: BD error
Unable to complete in 5 sec since the facet correction was started
Remedy: Polygon Motor error 1. Replace the Laser Scanner Unit

Code: E100-0003

Description: BD error
During the drive at the constant speed, the BD cycle is mismatched by -/+ 0.5% for 500 continuous msec
Remedy: Scanner Motor movement error or BD signal error 1.COPIER > FUNCTION > PART-CHK > MTR; and move M01 When the Scanner Motor (M01) moves 2-1. Check the flexible cable/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 3-1. Replace the Laser Scanner Unit 4-1. Replace the DC Controller PCB (UN09) When the Scanner Motor (M01) does not move 2-2. Check the harness/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 3-2. Replace the Laser Scanner Unit 4-2. Replace the DC Controller PCB (UN09)

Code: E110-0001

Description: Scanner Motor error
Scanner Motor movement error or motor control error
Remedy: Scanner Motor movement error or motor control error 1.Check the harness/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 2.Check the flexible cable/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 3. Replace the Laser Scanner Unit 4. Replace the DC Controller PCB (UN09)

Code: E110-0002

Description: Scanner Motor error
Scanner Motor movement error or motor control error
Remedy: Scanner Motor movement error or motor control error 1.Check the harness/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 2.Check the flexible cable/connector between the DC Controller PCB (UN09) and the Laser Scanner Unit 3. Replace the Laser Scanner Unit 4. Replace the DC Controller PCB (UN09)

Code: E110-0003

Description: Scanner Motor error
The signal fails to be 1 at laser sequence enable check
Remedy: Error in control with the Laser Scanner Unit 1. Replace the Laser Scanner Unit

Code: E194-0000

Description: Registration detection error
When the number of reading patterns fails to be the specified value
Remedy: The patch by the registration detection is not correctly created, or registration patch sensor error 1. Clean the dustproof glass. 2. Check density on the image visually. When the image density is light 3-1. Clean the high voltage contact point with dry wiping or air blower. 4-1. Replace the Drum Unit (If the color showing abnormality can be identified from the image, replace the Drum Unit for that color. otherwise, replace from the Drum Unit (Y) in order) 5-1.Check the harness/connector between the DC Controller PCB (UN09) and the High Voltage PCB 6-1.Replace the High Voltage PCB. Primary Charging High Voltage PCB (UN06), Developing High Voltage PCB (UN07), Auxiliary High Voltage PCB (UN08), Primary Transfer High Voltage PCB (UN04) 7-1 Replace the DCON When the image density is not light 3-2. Use your hand to check that the shutter of the Registration Patch Sensor Unit can be open 4-2. Check for soil on the window of the Patch Sensor (UN43, UN44) 5-2.Check scar on the ITB. 6-2. Check movement of the Registration Shutter Solenoid COPIER > FUNCTION > PART-CHK > SL to move SL02 7-2.Check the harness/connector between the DC Controller PCB (UN09/J12) and the Patch Sensor (UN43/J4007, UN44/ J4006) 8-2. Replace the Registration Patch Sensor Unit 9-2 Replace the ITB Unit.

Code: E194-0001

Description: Registration detection error
When there is an image gap of 3.25[mm] or larger.
Remedy: The last registration detection was not properly executed 1. Clear the registration detection data COPIER>FUNCTION>CLEAR>REG-CLR 2. Clean the window of the scanner 3. Check density on the image visually. When the image density is light 4-1. Clean the high voltage contact point with dry wiping or air blower. 5-1. Replace the Drum Unit (If the color showing abnormality can be identified from the image, replace the Drum Unit for that color. otherwise, replace from the Drum Unit (Y) in order) 6-1. Check the harness/connector between the DCON and the High Voltage PCB 7-1.Replace the High Voltage PCB. Primary Charging High Voltage PCB (UN06), Developing High Voltage PCB (UN07), Auxiliary High Voltage PCB (UN08), Primary Transfer High Voltage PCB (UN04) 8-1 Replace the DCON When the image density is not light 4-2.Use your hand to check that the shutter of the Registration Patch Sensor Unit can be open 5-2. Check for soil on the window of the Patch Sensor (UN43, UN44) 6-2.Check scar on the ITB. 7-2. Check movement of the Registration Shutter Solenoid COPIER > FUNCTION > PART-CHK > SL to move SL02 8-2. Check the harness/connector between the DC Controller PCB (UN09) and the Patch Sensor (UN43/J4007, UN44/J4006) 9-2. Replace the Registration Patch Sensor Unit 10-2 Replace the ITB Unit.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie