Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C2020F — Trang 13/45

Code: E025-0210

Description: Toner Container Motor (C) lock detection
Error in the current value after turning ON the motor.
Remedy: Overload of the motor or motor failure 1. Check if the Toner Bottle (C) is installed 2. Check the harness/connector between the DC Controller PCB (UN09) and the Toner Container Motor (C) (M11) 3. Check conduction of FU3 in the DC Controller PCB (UN09) 4. Replace the DC Controller PCB (UN09) 5. Replace the Hopper Unit (C)

Code: E025-0220

Description: Detection of short-circuit with Toner Container Motor (C)FET
Error in element in the DC Controller PCB Error in the current value after turning OFF the motor.
Remedy: Error in element in the DC Controller PCB 1.Replace the DC Controller PCB (UN09)

Code: E025-0230

Description: Detection of short-circuit with Toner Container Motor (C) GND
After turning ON the motor, the current value is a certain value or lower.
Remedy: Short-circuit failure of the Toner Bottle Motor or error in element in the DC Controller PCB 1. Check the harness between the DC Controller (UN09/J24) and the Toner Container Motor (C) (M11) 2. Replace the DC Controller PCB (UN09) 3. Replace the Hopper Unit (C)

Code: E025-0300

Description: Toner Supply Motor (Bk) lock detection
The Rotation Sensor does not detect rotation although 5 sec has passed since the motor was turned ON
Remedy: Overload of the motor or motor failure 1. Check conduction of FU9 on the DC Controller PCB (UN09). 2. Check the harness/connector between the DC Controller PCB (UN09/J26) and PS09 3. Replace the DC Controller PCB (UN09) 4. Check the Hopper Unit (Bk). 5. Replace the Hopper Unit (Bk).

Code: E025-0310

Description: Toner Container Motor (Bk) lock detection
Error in the current value after turning ON the motor.
Remedy: Overload of the motor or motor failure 1. Check if the Toner Bottle (Bk) is installed 2. Check the harness/connector between the DC Controller PCB (UN09) and the B Toner Container Motor (Bk)(M13) 3. Check conduction of FU3 in the DC Controller PCB (UN09) 4. Replace the DC Controller PCB (UN09) 5. Replace the Hopper Unit (Bk)

Code: E025-0320

Description: Detection of short-circuit with Toner Container Motor (Bk)FET
Error in element in the DC Controller PCB Error in the current value after turning OFF the motor.
Remedy: Error in element in the DC Controller PCB 1.Replace the DC Controller PCB (UN09)

Code: E025-0330

Description: Detection of short-circuit with Toner Container Motor (Bk) GND
After turning ON the motor, the current value is a certain value or lower
Remedy: Short-circuit failure of the Toner Bottle Motor or error in element in the DC Controller PCB 1. Check the harness between the DC Controller (UN09/J26) and the Toner Container Motor (Bk) (M13) 2. Replace the DC Controller PCB (UN09) 3. Replace the Hopper Unit (Bk)

Code: E032-0001

Description: ASSIST Counter failed to work
Detection of short-circuit with the Count Pulse Signal
Remedy: Check the cable (to see if it’s disconnected)
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie