Remedy: High Voltage contact point error or DC Controller PCB error When this symptom occurs regularly 1-1. Replace the DC Controller PCB (UN09) When this symptom occurs incidentally 1-2. Check the high voltage contact point and clean the Primary Transfer Roller Shaft Support 2-2. Replace the DC Controller PCB (UN09)
Remedy: High Voltage contact point error or DC Controller PCB error When this symptom occurs regularly 1-1. Replace the DC Controller PCB (UN09) When this symptom occurs incidentally 1-2. Check the high voltage contact point and clean the Primary Transfer Roller Shaft Support 2-2. Replace the DC Controller PCB (UN09)
Description: There is an error in the detection of the Scanner Unit home position.
The attempt to detect the home position fails when the Scanner Unit is moved forward.
Remedy: 1.Disconnect and then connect the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)64Pin). 2.Replace the flexible cable. 3.Replace the Scanner Unit HP sensor(SR1). 4.Replace the Scanner Motor(M1). 5.Replace the Relay PCB(PCB1). 6.Replace the Main Controller2 PCB(UN12)
Description: There is an error in the detection of the Scanner Unit home position.
The attempt to detect the home position fails when the Scanner Unit is moved back.
Remedy: 1.Disconnect and then connect the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)64Pin). 2.Replace the flexible cable. 3.Replace the Scanner Unit HP sensor(SR1). 4.Replace the Scanner Motor(M1). 5.Replace the Relay PCB(PCB1). 6.Replace the Main Controller2 PCB(UN12)
Description: The light intensity of the Scanner Unit is faulty.
The light intensity of the Scanner Unit during shading is under the specified level.
Remedy: 1.Disconnect and then connect the flexible cable. 2.Replace the flexible cable. 3.Replace the Scanner Unit. 4.Replace the Relay PCB(PCB1). 5.Replace the Main Controller2 PCB(UN12).