Description: The reader unit power supply (24V) is faulty.
At the start of a job, the 24V port is off.
Remedy: 1.Disconnect and then connect the power supply harness connector. 2.Replace the Power Supply PCB(UN1).
Code: E227-0003
Description: At the end of a job, the 24V port is off.
Remedy: 1.Disconnect and then connect the power supply harness connector. 2.Replace the Power Supply PCB(UN1).
Code: E227-0004
Description: The reader unit power supply (24V) is faulty.
When a load is being driven, the 24V port is off.
Remedy: 1.Disconnect and then connect the power supply harness connector. 2.Replace the Power Supply PCB(UN1).
Code: E240-0000
Description: Communication data error
Connection error between the DC Controller PCB and Main Controller PCB 2, or error in Main Controller PCB 2.
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Code: E240-0001
Description: Communication data error
60 sec while waiting for a pickup request
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Code: E240-0002
Description: Communication data error
60 sec while waiting for an image output request
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Code: E240-0003
Description: Communication data error
After a paper jam, 60 sec has passed without stopping
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Code: E240-0004
Description: Communication data error
60 sec has passed while waiting for completion of the initial rotation