Các lỗi thường gặp

Code :
  • Code: E719-0002
  • Description: Coin vendor error
    IPC error at coin vendor operation - Open circuit of IPC, unable to recover the IPC communication - When open circuit of the pickup/delivery signal cable is detected - Invalid connection is detected
  • Remedy: Check cable connection between the charging management equipment and the host machine While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment (To prevent a misuse by removing the charging management equipment, this error code is displayed)
  • Code: E719-0003
  • Description: Coin vendor erro
    r- Communication error with the coin manager occurs during unit price acquisition at startup.
  • Remedy: Check cable connection between the charging management equipment and the host machine While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment (To prevent a misuse by removing the charging management equipment, this error code is displayed)
  • Code: E719-0004
  • Description: Coin vendor error
    The coin vendor was connected to a model that does not support the coin vendor
  • Remedy: 1. Disconnect the coin vendor
  • Code: E719-0011
  • Description: Coin vendor error
    Error when the NewCardReader is started - The NewCardReader, which must have been connected before the power was turned OFF, is not connected when the power is turned ON)
  • Remedy: Check cable connection between the charging management equipment and the host machine While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment (To prevent a misuse by removing the charging management equipment, this error code is displayed)
  • Code: E719-0012
  • Description: Coin vendor error
    IPC error at NewCardReader operation Open circuit of IPC, unable to recover the IPC communication
  • Remedy: Check cable connection between the charging management equipment and the host machine While the charging management equipment is connected for operation, clear the error in the case of switching to the operation without the charging management equipment (To prevent a misuse by removing the charging management equipment, this error code is displayed)
  • Code: E719-0031
  • Description: Serial communication error when the NewCardReader is started
    Unable to start communication with the Serial NewCardReader at startup
  • Remedy: 1. Check if the cable of Serial NewCardReader is open circuit 2. Remove the Serial NewCardReader COPIER > Function > CLEAR > CARD COPIER > Function > CLEAR > ERR
  • Code: E719-0032
  • Description: Serial communication error after the NewCardReader was started
    Although communication with the Card Reader was possible at startup, it became unavailable in the middle of communication
  • Remedy: Check if the NewCardReader cable is open circuit
  • Code: E730-1001
  • Description: PDL software error
    Initialization error
  • Remedy: 1. PDL reset processing (user mode > function settings > printer > printer settings > utility > Reset Printer) 2. Turn OFF and then ON the power