Description: Device abnormal completion
An abnormal signal from the Main Controller PCB 2 to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0540
Description: Device timeout
An image synchronous signal from the Main Controller PCB 2 to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0541
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB 2 to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0550
Description: Device timeout
An image synchronous signal from the Main Controller PCB 2 to the Reader is not received within 30 seconds.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E315-0551
Description: Device abnormal completion
An abnormal signal from the Main Controller PCB 2 to the Reader is detected.
Remedy: 1. Turn OFF and then ON the main power. 2. Check the connection of the Main Controller PCB 2 (including the flat cable). 3. Replace the flat cable. 4. Replace the Main Controller PCB 2.
Code: E350
Description: System error
Remedy: Contact the service company office
Code: E351-0000
Description: Main Controller PCB 2 communication error
Remedy: 1. Turn OFF and then ON the main power 2. Disconnect and then connect the connector of the Main Controller PCB 2. 3. Replace the Main Controller PCB 2.