Description: Communication data error
60 sec has passed while waiting for the start of auto adjustment at warm-up rotation
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: Communication data error
Data access error
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: Communication data error
Time notification error
Remedy: 1. Disconnect and then connect the FFC (FFC07) that is connected to the DC Controller PCB (UN09) and Main Controller PCB 2 (UN12) 2. Replace Main Controller PCB 2 (UN12) 3. Replace the DC Controller PCB (UN09)
Description: EEPROM error (Scanner Unit)
An error has occurred at power-on.
Remedy: 1.Disconnect and then connedt the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)50pin). 2.Disconnect and then connect the flexible cable(Scanner Unit- Relay PCB(PCB1)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the Scanner Unit. 6.Replace the Relay PCB(PCB1) 7.Replace the Power Supply PCB(PCB1). 8.Replace the Main Controller2 PCB(UN12).
Description: EEPROM error (Scanner Unit)
An error has occurred during write operation.
Remedy: 1.Disconnect and then connedt the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)50pin). 2.Disconnect and then connect the flexible cable(Scanner Unit- Relay PCB(PCB1)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the Scanner Unit. 6.Replace the Relay PCB(PCB1) 7.Replace the Power Supply PCB(PCB1). 8.Replace the Main Controller2 PCB(UN12).
Description: EEPROM error (Scanner Unit)
An error has occurred during read operation following write operation.
Remedy: 1.Disconnect and then connedt the flexible cable(Relay PCB(PCB1)-Main Controller2 PCB(UN12)50pin). 2.Disconnect and then connect the flexible cable(Scanner Unit- Relay PCB(PCB1)). 3.Disconnect and then connect the power supply harness connector. 4.Replace the flexible cable. 5.Replace the Scanner Unit. 6.Replace the Relay PCB(PCB1) 7.Replace the Power Supply PCB(PCB1). 8.Replace the Main Controller2 PCB(UN12).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.