Description: Toner Container Motor (Y) lock detection
Error in the current value after turning ON the motor.
Remedy: Overload of the motor or motor failure 1. Check if the Toner Bottle (Y) is installed 2. Check the harness/connector between the DC Controller PCB (UN09) and the Toner Container Motor (Y) (M07) 3. Check conduction of FU1 in the DC Controller PCB (UN09) 4. Replace the DC Controller PCB (UN09) 5. Replace the Hopper Unit (Y)
Description: Detection of short-circuit with Toner Container Motor (Y)FET
Error in element in the DC Controller PCB Error in the current value after turning OFF the motor.
Description: Detection of short-circuit with Toner Container Motor (Y) GND
After turning ON the motor, the current value is a certain value or lower.
Remedy: Short-circuit failure of the Toner Bottle Motor or error in element in the DC Controller PCB 1. Check the harness between the DC Controller (UN09/J23) and the Toner Container Motor (Y) (M07) 2. Replace the DC Controller PCB (UN09) 3. Replace the Hopper Unit (Y)
Description: Toner Supply Motor (M) lock detection
The Rotation Sensor does not detect rotation although 5 sec has passed since the motor was turned ON
Remedy: Overload of the motor or motor failure 1. Check conduction with FU2 on the DC Controller PCB (UN09) 2. Check the harness/connector between the DC Controller PCB (UN09/J24) and PS07. 3. Replace the DC Controller PCB (UN09) 4. Check the Hopper Unit (M). 5. Replace the Hopper Unit (M).
Description: Toner Container Motor (M) lock detection
Error in the current value after turning ON the motor.
Remedy: Overload of the motor or motor failure 1. Check if the Toner Bottle (M) is installed 2. Check the harness/connector between the DC Controller PCB (UN09) and the Toner Container Motor (M) (M09) 3. Check conduction of FU1 in the DC Controller PCB (UN09) 4. Replace the DC Controller PCB (UN09) 5. Replace the Hopper Unit (M)
Description: Detection of short-circuit with Toner Container Motor (M)FET
Error in element in the DC Controller PCB Error in the current value after turning OFF the motor.
Remedy: Error in element in the DC Controller PCB 1.Replace the DC Controller PCB (UN09)
Description: Detection of short-circuit with Toner Container Motor (M) GND
After turning ON the motor, the current value is a certain value or lower.
Remedy: Short-circuit failure of the Toner Bottle Motor or error in element in the DC Controller PCB 1. Check the harness between the DC Controller (UN09/J24) and the Toner Container Motor (M) (M09) 2. Replace the DC Controller PCB (UN09) 3. Replace the Hopper Unit (M)
Description: Toner Supply Motor (C) lock detection
After turning ON the motor, the rotation sensor does not detect although a specified period of time has passed.
Remedy: Overload of the motor or motor failure 1. Check conduction of FU9 on the DC Controller PCB (UN09). 2. Check the harness/connector between the DC Controller PCB (UN09/J24) and PS08. 3. Replace the DC Controller PCB (UN09) 4. Check the Hopper Unit (C). 5. Replace the Hopper Unit (C).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.