Code: E025-0010

Description: Toner Container Motor (Y) lock detection
Error in the current value after turning ON the motor.
Remedy: Overload of the motor or motor failure 1. Check if the Toner Bottle (Y) is installed 2. Check the harness/connector between the DC Controller PCB (UN09) and the Toner Container Motor (Y) (M07) 3. Check conduction of FU1 in the DC Controller PCB (UN09) 4. Replace the DC Controller PCB (UN09) 5. Replace the Hopper Unit (Y)

Code: E025-0020

Description: Detection of short-circuit with Toner Container Motor (Y)FET
Error in element in the DC Controller PCB Error in the current value after turning OFF the motor.
Remedy: 1.Replace the DC Controller PCB (UN09)

Code: E025-0030

Description: Detection of short-circuit with Toner Container Motor (Y) GND
After turning ON the motor, the current value is a certain value or lower.
Remedy: Short-circuit failure of the Toner Bottle Motor or error in element in the DC Controller PCB 1. Check the harness between the DC Controller (UN09/J23) and the Toner Container Motor (Y) (M07) 2. Replace the DC Controller PCB (UN09) 3. Replace the Hopper Unit (Y)

Code: E025-0100

Description: Toner Supply Motor (M) lock detection
The Rotation Sensor does not detect rotation although 5 sec has passed since the motor was turned ON
Remedy: Overload of the motor or motor failure 1. Check conduction with FU2 on the DC Controller PCB (UN09) 2. Check the harness/connector between the DC Controller PCB (UN09/J24) and PS07. 3. Replace the DC Controller PCB (UN09) 4. Check the Hopper Unit (M). 5. Replace the Hopper Unit (M).

Code: E025-0110

Description: Toner Container Motor (M) lock detection
Error in the current value after turning ON the motor.
Remedy: Overload of the motor or motor failure 1. Check if the Toner Bottle (M) is installed 2. Check the harness/connector between the DC Controller PCB (UN09) and the Toner Container Motor (M) (M09) 3. Check conduction of FU1 in the DC Controller PCB (UN09) 4. Replace the DC Controller PCB (UN09) 5. Replace the Hopper Unit (M)

Code: E025-0120

Description: Detection of short-circuit with Toner Container Motor (M)FET
Error in element in the DC Controller PCB Error in the current value after turning OFF the motor.
Remedy: Error in element in the DC Controller PCB 1.Replace the DC Controller PCB (UN09)

Code: E025-0130

Description: Detection of short-circuit with Toner Container Motor (M) GND
After turning ON the motor, the current value is a certain value or lower.
Remedy: Short-circuit failure of the Toner Bottle Motor or error in element in the DC Controller PCB 1. Check the harness between the DC Controller (UN09/J24) and the Toner Container Motor (M) (M09) 2. Replace the DC Controller PCB (UN09) 3. Replace the Hopper Unit (M)

Code: E025-0200

Description: Toner Supply Motor (C) lock detection
After turning ON the motor, the rotation sensor does not detect although a specified period of time has passed.
Remedy: Overload of the motor or motor failure 1. Check conduction of FU9 on the DC Controller PCB (UN09). 2. Check the harness/connector between the DC Controller PCB (UN09/J24) and PS08. 3. Replace the DC Controller PCB (UN09) 4. Check the Hopper Unit (C). 5. Replace the Hopper Unit (C).