Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C355i — Trang 15/44

Code: E246-0005-00

Description: System error
Causes: System error
Remedy: Contact to the sales company.

Code: E247-0001-00

Description: System error
Causes: System error
Remedy: Contact to the sales company.

Code: E247-0002-00

Description: System error
Causes: System error
Remedy: Contact to the sales company.

Code: E247-0003-00

Description: System error
Causes: System error
Remedy: Contact to the sales company.

Code: E247-0004-00

Description: System error
Causes: System error
Remedy: Contact to the sales company.

Code: E248-0001-04

Description: Reader backup error
Causes: Reading error was detected when the Controller IC of the Main Controller PCB read the Reader backup value in the Flash PCB.
Remedy: [Related parts] R1.00 - Flash PCB (UN91) - Main Controller PCB (UN81) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy, enter the value of the service label again. 1. After executing "COPIER> FUNCTION> CLEAR> R-CON", turn OFF and then ON the main power, and check whether the error is cleared. 2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive. 3. Replace the Main Controller PCB.

Code: E248-0002-04

Description: Reader backup error
Causes: The Controller IC of the Main Controller PCB failed to rewrite the Reader backup value in the Flash PCB.
Remedy: [Related parts] R1.00 - Flash PCB (UN91) - Main Controller PCB (UN81) [Remedy] Perform the following in the order while checking whether the error is cleared. After performing the remedy, enter the value of the service label again. 1. After executing "COPIER> FUNCTION> CLEAR> R-CON", turn OFF and then ON the main power, and check whether the error is cleared. 2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive. 3. Replace the Main Controller PCB.

Code: E280-0001-04

Description: Scanner Unit communication error
Causes: Communication between the Main Controller and the Scanner Unit (front) was not started within the specified period of time.
Remedy: [Related parts] R1.00 - Harness between the Scanner Unit (front) and the Main Controller PCB (UN81) - Scanner Unit (front) - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie