Causes: Image sampling for shading was not completed.
Remedy: [Related parts] R1.00 - Harness between the Scanner Unit (back) and the Main Controller PCB (UN81) - Scanner Unit (back) - ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Causes: Image compression process was not completed within the specified period of time at scanning.
Remedy: [Related parts] R1.00 - Harness between the Reader Unit and Main Controller PCB - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the related harness/cable, connector and parts.
Causes: Processing of a JBIG-compressed data was not completed within the specified period of time at printing or SEND.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the Main Controller PCB.
Causes: Image processing (change in magnification ratio, rotating, and shifting) was not completed normally within the specified period of time.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the Main Controller PCB.
Causes: Processing to clear image data in the memory was not completed normally within the specified period of time.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the Main Controller PCB.
Causes: Transfer of image signal was not completed within the specified period of time at scanning.
Remedy: [Related parts] R1.00 - Harness between the Reader Unit and Main Controller PCB - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the related harness/cable, connector and parts.
Causes: Image processing was not completed within the specified period of time at scanning.
Remedy: [Related parts] R1.00 - Harness between the Reader Unit and Main Controller PCB - Main Controller PCB - Reader Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the related harness/cable, connector and parts.
Causes: Compression processing of the scanned image into JPEG was terminated abnormally.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. Reinstall the latest system software using SST or a USB flash drive. 2. Check/replace the Main Controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.