Causes: Connection of the Cassette Pedestal could not be detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN04/J190), the Drawer Unit (DR03/J5904) and the Cassette Module Controller PCB - Cassette Module Controller PCB - Cassette Pedestal - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Remedy: [Related parts] R1.00 - Harness between the Main Controller PCB and the HDD - HDD - Main Controller PCB [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Format the HDD and reinstall the system software using SST or a USB flash drive. 2. Check/replace the related harness/cable, connector and parts.
Remedy: [Related parts] R1.00 - Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (UN81/J4001, 4002) - READER ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Causes: A signal to start image transfer could not be detected at scanning although the specified period of time (120 sec) has passed.
Remedy: [Related parts] R1.00 - Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (UN81/J4001, 4002) - READER ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Causes: A communication error between the Reader Controller PCB and the Main Controller PCB was detected.
Remedy: [Related parts] R1.00 - Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (UN81/J4001, 4002) - READER ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Causes: A communication error between the Reader Controller PCB and the Main Controller PCB was detected.
Remedy: [Related parts] R1.00 - Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (UN81/J4001, 4002) - READER ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally
Causes: A communication error between the Reader Controller PCB and the Main Controller PCB was detected.
Remedy: [Related parts] R1.00 - Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (UN81/J4001, 4002) - READER ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Causes: DDI-S communication error (SPRDY-S detection error)
Remedy: [Related parts] R1.00 - Harness between the READER ADF UNIT (J6, J5) and the Main Controller PCB (UN81/J4001, 4002) - READER ADF UNIT - Main Controller PCB (UN81) [Remedy] Check/replace the related parts. After performing the remedy, check that the copy image is output normally.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.