Các lỗi thường gặp

Code :
  • Code: E009-0002-05
  • Description: Fixing disengagement timeout error
  • Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.01 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Harness between the Low-voltage Power Supply PCB (UN01/J315 and J322) and the DC Controller PCB (UN04/J20 and J22) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - Low Voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If periodic sound has occurred, check/replace the Fixing Assembly, Low-voltage Power Supply PCB, DC Controller PCB, and related harness. 2. If the Delivery Roller is rotating without noise, or if noise of the gear teeth being improperly meshed has occurred, check/replace the Fixing Drive Unit. 3. If the Delivery Roller is not rotating, check/replace the Fixing Motor, Fixing Drive Unit, Lowvoltage Power Supply PCB, DC Controller PCB, and related harness. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0003-05
  • Description: Fixing pressure retry error
  • Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. Be sure to preferentially check the Fixing Drive Unit. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0004-05
  • Description: Fixing disengagement retry error
  • Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. Be sure to preferentially check the Fixing Drive Unit. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0005-05
  • Description: Fixing disengagement timeout error
  • Causes: At retry of engagement operation of the Fixing Pressure Release Cam, the Fixing Pressure Release Sensor did not detect disengagement state within 4 sec after the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. Be sure to preferentially check the Fixing Drive Unit. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0006-05
  • Description: Fixing disengagement timeout error
  • Causes: At retry of disengagement operation of the Fixing Pressure Release Cam, the Fixing Pressure Release Sensor did not detect engagement state within 4 sec after the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.01 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. Be sure to preferentially check the Fixing Drive Unit. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E010-0001-05
  • Description: Bk Drum_ITB Motor error
  • Causes: It did not become the specified speed for 500 consecutive msec although 1000 msec have passed from the startup of the Bk Drum_ITB Motor in the Main Drive Unit. (The detection timing varies depending on the paper feed conditions.)
  • Remedy: [Related parts] R1.00 - Harness between the Bk Drum_ITB Motor (M02/J5702) and the DC Controller PCB (UN04/J140) - Fuse in the Low-voltage Power Supply PCB (UN01/FU14) - Bk Drum_ITB Motor (M02) - Main Drive Unit - Low-voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB. 2. Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester. a. If power is flowing to it (the measurement value is less than 1 ohm), 1. Replace the Bk Drum_ITB Motor. 2. Replace the DC Controller PCB. b. If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Lowvoltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E010-0002-05
  • Description: Bk Drum_ITB Motor error
  • Causes: The specified speed could not be detected for 500 consecutive msec although it became the specified speed at least once from the startup of the Bk Drum_ITB Motor in the Main Drive Unit.
  • Remedy: [Related parts] R1.00 - Harness between the Bk Drum_ITB Motor (M02/J5702) and the DC Controller PCB (UN04/J140) - Fuse in the Low-voltage Power Supply PCB (UN01/FU14) - Bk Drum_ITB Motor (M02) - Main Drive Unit - Low-voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB. 2. Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester. a. If power is flowing to it (the measurement value is less than 1 ohm), 1. Replace the Bk Drum_ITB Motor. 2. Replace the DC Controller PCB. b. If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Lowvoltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E010-0003-05
  • Description: Bk Drum_ITB Motor error
  • Causes: There was no FG signal input for 300 msec from the startup of the Bk Drum_ITB Motor in the Main Drive Unit.
  • Remedy: [Related parts] R1.00 - Harness between the Bk Drum_ITB Motor (M02/J5702) and the DC Controller PCB (UN04/J140) - Fuse in the Low-voltage Power Supply PCB (UN01/FU14) - Bk Drum_ITB Motor (M02) - Main Drive Unit - Low-voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check whether the gears of the Main Drive Unit can be rotated by hand. a. If they cannot be rotated, replace the Main Drive Unit. b. If they can be rotated, check the harnesses from the Bk Drum_ITB Motor to the DC Controller PCB. 2. Measure the both ends of the fuse in the Low-voltage Power Supply PCB using a tester. a. If power is flowing to it (the measurement value is less than 1 ohm), 1. Replace the Bk Drum_ITB Motor. 2. Replace the DC Controller PCB. b. If the power is not flowing to it (the measurement value is 1 ohm or higher), replace the Lowvoltage Power Supply PCB. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES