Code: E193-0000-05

Description: Communication error
Causes: NACK was received twice at communication retry of image ASIC.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - Main Controller PCB (UN81) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E193-0101-05

Description: Communication error
Causes: There was no response at communication retry of image ASIC.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J112) and the Main Controller PCB (UN81/ J4511) - Main Controller PCB (UN81) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E193-0F00-05

Description: Communication error
Causes: Image ASIC could not be sent due to insufficient software memory.
Remedy: [Remedy] Turn OFF and then ON the main power. [Reference] Data (device information) is reset by turning OFF and then ON the main power.

Code: E196-0000-05

Description: EEPROM communication error
Causes: The NACK (a negative reply sent by the reception side to the sending side) was received for 3 times in communication from the DC Controller PCB (CPU) to the DCON EEPROM on the DC Controller PCB.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Harness between the DC Controller PCB (UN04/J184) and the Developing High-voltage PCB (UN06/J241) - Y/M/C/Bk Laser Driver PCB (UN05) - Developing High-voltage PCB (UN06) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E196-0001-05

Description: EEPROM communication error
Causes: Although access to the DCON EEPROM from the DC Controller PCB (CPU) was performed for 3 times, no response was received and timeout occurred.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Harness between the DC Controller PCB (UN04/J184) and the Developing High-voltage PCB (UN06/J241) - Y/M/C/Bk Laser Driver PCB (UN05) - Developing High-voltage PCB (UN06) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E196-0002-05

Description: EEPROM communication error
Causes: Although write polling to the DCON EEPROM from the DC Controller PCB (CPU) was performed for 3 times, no response was received and timeout occurred.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Harness between the DC Controller PCB (UN04/J184) and the Developing High-voltage PCB (UN06/J241) - Y/M/C/Bk Laser Driver PCB (UN05) - Developing High-voltage PCB (UN06) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E196-0003-05

Description: EEPROM communication error
Causes: EEPROM data in DCON could not be read at startup.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J110) and the Y/M/C/Bk Laser Driver PCB (UN05/J202) - Harness between the DC Controller PCB (UN04/J184) and the Developing High-voltage PCB (UN06/J241) - Y/M/C/Bk Laser Driver PCB (UN05) - Developing High-voltage PCB (UN06) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: E196-000F-05

Description: EEPROM communication error
Causes: The number of read/write job data (device information) to the DCON EEPROM exceeded the specified value.
Remedy: [Remedy] Turn OFF and then ON the main power. [Reference] Data (device information) is reset by turning OFF and then ON the main power.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie