Các lỗi thường gặp

Code :
  • Code: E674-0021-07
  • Description: Fax Board communication error
  • Causes: A Fax Board for non-supported modem has been connected.
  • Remedy: Replace it with a genuine Fax Board (for 1-line or 2-line).
  • Code: E674-0030-07
  • Description: Fax Board communication error
  • Causes: Check sum error
  • Remedy: System software download for 2 line FAX
  • Code: E674-0100-07
  • Description: Fax Board communication error
  • Causes: After completion of fax communication, writing of the communication information (log) failed, and the log could not be read.
  • Remedy: Turn OFF and then ON the main power. [CAUTION] The previous communication information (log) will be cleared by turning OFF and then ON the main power.
  • Code: E674-0300-07
  • Description: Fax configuration error
  • Causes: It was detected that there was a Fax Board for multiple lines installed while the IP Fax license was enabled.
  • Remedy: - Remove the Fax Board for multiple lines to use the machine as an IP Fax model. - Uninstall the IP Fax license to use the machine as a G3 Fax model.
  • Code: E674-0301-07
  • Description: Fax configuration error
  • Causes: It was detected that there was no 1-line Fax Board installed while the IP Fax license was enabled.
  • Remedy: - Install the Fax Board (1-line) to use the machine as an IP Fax model. - Uninstall the IP Fax license and install the G3 Fax Board to use the machine as a G3 Fax model.
  • Code: E713-0000-05
  • Description: Communication error
  • Causes: The operation was not completed although retry of the communication between the host machine (Dcon) and the Finisher was performed for 3 consecutive times.
  • Remedy: [Remedy] Perform the following in the order while checking whether the error is cleared. 1. Check that the connector of the Interface Harness is not disconnected. 2. Replace the Finisher Controller PCB. 3. Replace the Interface Harness.
  • Code: E719-0001-00
  • Description: Error in Coin Vendor.
  • Causes: Error in starting of the CoinVendor - The Coin Vendor, which should have been connected before the power was turned OFF, is not connected when the power is turned ON.
  • Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
  • Code: E719-0002-00
  • Description: Error in Coin Vendor.
  • Causes: Error in IPC when CoinVendor is running. - In the case of disconnection of IPC or an error in which IPC communication failed to be recovered. - When disconnection of the pickup delivery signal is detected. - When illegal connection is detected (short-circuit with Tx and Rx of IPC)
  • Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)