Causes: - In the case of communication error with the coin vendor while obtaining the unit price at start-up.
Remedy: Check the connection between charging management equipment and machine, and check that the Cable is not open-circuit. Clear the error while the charging management equipment is connected to operate and when switching to the operation without charging management equipment. (To prevent the misuse by removing the charging management equipment, this error code is displayed.)
Code: E719-0004-00
Description: Coin vendor error
Causes: The coin vendor was connected to a model that does not support the coin vendor
Remedy: Cancel the connection of the coin vendor and clear the error.
Code: E719-0031-00
Description: Error in serial communication at the start of the New Card Reader
Causes: Failure in communication with the serial New Card Reader at start-up.
Remedy: - Check if the cable of the serial New Card Reader is disconnected. - Take out the serial New Card Reader. - COPIER > Function > CLEAR > CARD - COPIER > Function > CLEAR > ERR
Code: E719-0032-00
Description: Error in serial communication at the start of the New Card Reader
Causes: Communication failed in the middle of the operation although communication with the serial New Card Reader was successful at start-up
Remedy: - Check if the cable of the serial New Card Reader is disconnected.
Code: E719-0041-00
Description: Coin vendor error
Causes: Communication with the coin vendor could not be established at startup of the host machine. (Charge mode (COIN = 6) has been set.)
Remedy: 1. If it operates in charge mode (COIN = 6) - Check that it is the supported charging management equipment. - Check the cable to be connected. - Check the power of the charging management equipment. 2. If charge mode is canceled - Select COPIER> OPTION> ACC> COIN> "0", and turn OFF and then ON the main power.
Code: E719-0042-00
Description: Coin vendor error
Causes: Communication with the coin vendor could not be established at startup of the host machine. (Charge mode (COIN = 6) has been set.)
Remedy: 1. If it operates in charge mode (COIN = 6) - Check that it is the supported charging management equipment. - Check the cable to be connected. - Check the power of the charging management equipment. 2. If charge mode is canceled - Select COPIER> OPTION> ACC> COIN> "0", and turn OFF and then ON the main power.