Description: DF Disengagement Motor error
Lead Roller 1 disengagement error
Remedy: 1. Open the ADF Front Cover, and then check the operation of active Disengagement Motor. 2. Check the physical position of Disengaging HP Sensor and its flag. 3. Check that the Cable of Disengaging HP Sensor is not open-circuit. 4. Replace the DF Driver PCB.
Description: DF Disengagement Motor error
Lead Roller 1 disengagement error
Remedy: 1. Open the ADF Front Cover, and then check the operation of active Disengagement Motor. 2. Check the physical position of Disengaging HP Sensor and its flag. 3. Check that the Cable of Disengaging HP Sensor is not open-circuit. 4. Replace the DF Driver PCB.
Description: DF Disengagement Motor error
Lead Roller 2 disengagement error
Remedy: 1. Open the ADF Front Cover, and then check the operation of active Disengagement Motor. 2. Check the physical position of Disengaging HP Sensor and its flag. 3. Check that the Cable of Disengaging HP Sensor is not open-circuit. 4. Replace the DF Driver PCB.
Description: DF Disengagement Motor error
Lead Roller 2 disengagement error
Remedy: 1. Open the ADF Front Cover, and then check the operation of active Disengagement Motor. 2. Check the physical position of Disengaging HP Sensor and its flag. 3. Check that the Cable of Disengaging HP Sensor is not open-circuit. 4. Replace the DF Driver PCB.
Description: DF Unit SDRAM error (This error occurs on Duplex Color Image Reader Unit-B1 only)
SDRAM access error
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Controller, and check that the Cable is not open-circuit. 3. Replace the Reader Controller PCB.
Description: DF Unit SDRAM error (This error occurs on Duplex Color Image Reader Unit-B1 only)
SDRAM Verify error
Remedy: 1. Turn OFF and then ON the power. 2. Check the connection between Reader and Controller, and check that the Cable is not open-circuit. 3. Replace the Reader Controller PCB.
Description: Different DF model
Installed DF is not the supported DF.
Remedy: 1. Using the service mode, check if the installed DF model is the same model which was set in the service mode. 2. Check the connection between Reader Controller PCB and DF Driver PCB, and check that the Cable is not open-circuit. 3. Replace the DF Driver PCB. 4. Replace the Reader Controller PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.