Causes: The OS kernel was not found. When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-4003-00
Description: Error in system on the Flash PCB
Causes: The OS boot loader was not found. When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-4010-00
Description: Error in system on the Flash PCB
Causes: The OS in safe mode could not be recognized. When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-4011-00
Description: Error in system on the Flash PCB
Causes: The file for booting the OS in safe mode was not found. When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-4012-00
Description: Error in system on the Flash PCB
Causes: The kernel in safe mode was not found. When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-9000-00
Description: Error in system on the Flash PCB
Causes: SRAM device access-related error (at startup) When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-9001-00
Description: Error in system on the Flash PCB
Causes: Error in memory allocation/invalid memory (at startup) When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.
Code: 614-9002-00
Description: Error in system on the Flash PCB
Causes: Setting file error was detected at startup. When this error occurs, the system has not been started normally. Therefore, it may not be recorded in the error log.
Remedy: Perform the following in the order while checking whether the error is cleared. 1. After turning OFF the main power, remove and then install the SATA Flash PCB again to check that it is properly installed. 2. Enter safe mode using (2+8) startup, and execute Flash Format using SST or a USB flash drive. 3. After replacing the SATA Flash PCB, reinstall the system software using SST or a USB flash drive.