Remedy: In case of first detection of the reader on printer model (‘Please power cycle’ message is only displayed on the user screen instead of an error code. Service mode> DISPLAY> ERR is recorded in error log.)
Description: Printer communication is abnormal. Failure of communication between the controller and DC controller
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller board
Description: Printer communication error. An error occurred to detect printer vertical synchronous signal.
Remedy: 1. Check the connection to the printer. ?¨ Connect the connector/replace the harness. 2. Check the power of the printer (check if the initialization operation is executed at startup). 3. Replace the DC Controller PCB/Main Controller PCB.
Description: Printer communication is abnormal. Printer vertical synchronizing signal detection failure
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller board
Description: Printer communication is abnormal. Communication error
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller board
Description: Printer communication is abnormal. Communication error
Remedy: 1. Connected connector check with the printer 2. The power supply check (check if initialization is executed in startup) of the printer 3. Replacement of DC controller or main controller b
Description: DDI communication error. The reader controller PCB detected a failure in communication between the main controller PCB and the reader controller PCB.
Remedy: 1. Failure of the connection between the main controller PCB and the reader controller PCB 2. Failure of the reader controller PCB (PCB1) 3. Failure of the main controller PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.