Description: Pickup roller unit up/down failure. Even when the pickup roller unit up/down motor (M10) is driven, the level of the pickup roller unit up/down home position sensor (SR12) does not change within a specified period.
Remedy: 1. Displacement/disconnection of the connector of the pickup roller unit up/down home position sensor (SR12) 2. Displacement/disconnection of the connector of the pickup roller unit up/down motor (M10) 3. Failure of the pickup roller unit up/down home position sensor 4. Failure of the pickup roller unit up/down motor
Description: Failure of the tray up/down motor (M8). Even when the tray up/down motor (M8) is driven, the tray home position sensor (SR13) is not turned ON or OFF within a specified period.
Remedy: 1. Displacement/disconnection of the connector of the tray home position sensor (SR13) 2. Displacement/disconnection of the connector of the tray up/down motor (M8) 3. Failure of the tray home position sensor 4. Failure of the tray up/down motor
Description: Failure of the tray up/down motor (M8). Even when the tray up/down motor (M8) is driven, the paper surface sensor (SR6) is not turned ON within a specified period.
Remedy: 1. Displacement/disconnection of the connector of the paper surface sensor (SR6) 2. Displacement/disconnection of the connector of the tray up/down motor (M8) 3. Failure of the paper surface sensor 4. Failure of the tray up/down motor
Description: Failure in drive of the Scanner Unit Cooling Fan (Reader Assembly). The Scanner Unit Cooling Fan was not driven.
Remedy: 1. Disconnect and then connect the connector. 2. Check if there is open circuit. 3. Replace the corresponding fan. 4. Replace the DADF Driver PCB.
Description: Failure to stop Scanner Unit Cooling Fan (Reader Assembly). The Scanner Unit Cooling Fan was not stopped.
Remedy: 1. Disconnect and then connect the connector. 2. Check if there is open circuit. 3. Replace the corresponding fan. 4. Replace the DADF Driver PCB.
Description: Failure in drive of the DADF Cooling Fan 3. DADF Cooling Fan 3 was not driven.
Remedy: 1. Disconnect and then connect the connector. 2. Check if there is open circuit. 3. Replace the corresponding fan. 4. Replace the DADF Driver PCB.
Description: Failure to stop DADF Cooling Fan 3. DADF Cooling Fan 3 was not stopped.
Remedy: 1. Disconnect and then connect the connector. 2. Check if there is open circuit. 3. Replace the corresponding fan. 4. Replace the DADF Driver PCB.
Description: Failure in drive of the DADF Cooling Fan 1 or 2.DADF Cooling Fan 1 or 2 was not driven.
Remedy: 1. Disconnect and then connect the connector. 2. Check if there is open circuit. 3. Replace the corresponding fan. 4. Replace the DADF Driver PCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.