Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR Advance C7270i — Trang 61/75

Code: E710-0001

Description: Printer IPC error. In case that IPC communication IC in the printer engine detected a failure when turning power ON
Remedy: Check the cable.

Code: E711-0001

Description: IPC communication is abnormal. When 4 or more error occurrence is set to the error register in IPC chip within 1.5 seconds.
Remedy: Check the cable.

Code: E711-0001

Description: IPC communication failure. Occurrence of an error was set in the error resistor of the IPC chip more than four times in 1.5 seconds.
Remedy: Check the cable.

Code: E713-0001

Description: Finisher communication error. Communication failed between the finisher and the host machine.
Remedy: 1. Check the cable connection. 2. Replace the finisher controller circuit PCB. 3. Replace the DC controller circuit PCB.

Code: E717-0001

Description: Communication with the NE controller is abnormal. Error in the NE controller start When the NE controller which should have been connected is not connected before the power off at power supply time to turn on
Remedy: Recover with service mode COPIER> FUNCTION> CLEAR> ERR after cable check

Code: E717-0002

Description: Communication with the NE controller is abnormal. IPC error in the NE controller operation In the case of the errors that disconnection of IPC, or IPC communication is unrecoverable.
Remedy: Recover with service mode COPIER> FUNCTION> CLEAR> ERR after cable check

Code: E719-0001

Description: Coin vendor failure. Error in the Coin vendor start When the Coin vendor which should have been connected is not connected before the power off at power supply time to turn on
Remedy: Recover with service mode COPIER> FUNCTION> CLEAR> ERR after cable check

Code: E719-0002

Description: Coin vendor failure. IPC error in the Coin vendor operation In the case of the errors that disconnection of IPC, or IPC communication is unrecoverable. In the case of connection failure detection for a signal of paper pickup/delivery In the case of the detection of improper connection
Remedy: Recover with service mode COPIER> FUNCTION> CLEAR> ERR after cable check