Causes: The 3.3 V supply to the high voltage PCB was not detected. (Blowout of FU16 on the DC Controller PCB)
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1253) and the Primary Charging High Voltage PCB (CL) (UN38/J3040) - Harness between the DC Controller PCB (UN2/J1254) and the Developing High Voltage PCB (CL) (UN40/J3045) - Primary Charging High Voltage PCB (CL) (UN38) - Developing High Voltage PCB (CL) (UN40) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: The 12 V supply to the PCB and the 24 V/12 V supply to the Power Supply Fan were not detected. (Blowout of FU5, 7, 9, 10, 11, 13 and 14 on the Relay PCB)
Remedy: [Related parts] R1.00 - Harness between the Relay PCB (UN7/J1816) and the Primary Charging High Voltage PCB (CL) (UN38/J3021) - Harness between the Relay PCB (UN7/J1821) and the Remote Shut Down Solenoid (SL9/J8230) - Harness between the Relay PCB (UN7/J1830) and the Power Supply Fan 1 (FM8/J7401) - Harness between the Relay PCB (UN7/J1811) and the Riser PCB (UN159/J14) - Harness between the Riser PCB (UN159/J17) and the FAX PCB (J2 and J5) - Harness between the Relay PCB (UN7/J1806) and the Finisher Lattice (J7512C) - Harness between the Relay PCB (UN7/J1806) and the Delivery Door Switch (SW5/J8237) - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - Harness between the DC Controller PCB (UN2/J1201) and the Front Door Switch (SW1/J8235) - Harness between the Relay PCB (UN7/J1815) and the Drum Driver PCB (UN6/J1900) - Harness between the Drum Driver PCB (UN6/J1925) and the Multi-purpose Tray Unit Switch (SW3/J8056) - Remote Shut Down Solenoid (SL9) - Power Supply Fan 1 (FM8) - Delivery Door Switch (SW5) - Front Door Switch (SW1) - Primary Charging High Voltage PCB (CL) (UN38) - Riser PCB (UN159) - Relay PCB (UN7) - Drum Driver PCB (UN6) - Multi-purpose Tray Unit Switch (SW3) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: The 24 V supply to the Developing Assembly Control PCB was not detected. (Blowout of FU8 on the DC Controller PCB)
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1252) and the Developing Assembly Control PCB (UN96/J1308) - Developing Assembly Control PCB (UN96) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Causes: The 24 V supply to the Relay PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the Relay PCB (UN7/J1802) and the DC Power Supply PCB (24VA) (UN34/ J202) - Harness between the AC Driver PCB (UN8/J810 and J813) and the DC Power Supply PCB (24VA) (UN34/J102) - Harness between the Relay PCB (UN7/J1821) and the Pickup Feed Driver PCB (UN4/J1480) - Harness between the Relay PCB (UN7/J1490) and the AC Driver PCB (UN8/J811) - DC Power Supply PCB (24VA) (UN34) - Relay PCB (UN7) - AC Driver PCB (UN8) - Pickup Feed Driver PCB (UN4) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: The 24 V supply to the Drum Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the Relay PCB (UN7/J1815) and the Drum Driver PCB (UN6/J1900) - Drum Driver PCB (UN6) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: The 24 V supply to the Fixing Feed Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the Relay PCB (UN7/J1816), the Drawer Unit (J8023) and the Fixing Feed Driver PCB (UN5/J1500) - Fixing Feed Driver PCB (UN5) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.
Causes: The 24 V supply to the DC Controller PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1200) and the Relay PCB (UN7/J1817) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.