Code: 262-2400-05

Description: Power supply error
Causes: The 24 V supply to the Drum Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the Relay PCB (UN7/J1815) and the Drum Driver PCB (UN6/J1900) - Drum Driver PCB (UN6) - Relay PCB (UN7) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 262-2410-05

Description: Power supply error
Causes: The 24 V supply to the Multi-purpose Tray Pickup Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the Drum Driver PCB (UN6/J1925) and the Multi-purpose Tray Pickup Driver PCB (UN97/J1350) - Multi-purpose Tray Pickup Driver PCB (UN97) - Drum Driver PCB (UN6) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 263-1110-05

Description: Power supply error
Causes: The 12 V supply to the Fixing Feed Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harnesses connecting the DC Controller PCB (UN2/J1222), the Drawer Unit (J8023) and the Fixing Feed Driver PCB (UN5/J1510) - Fixing Feed Driver PCB (UN5) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 263-1120-05

Description: Power supply error
Causes: The 12 V supply to the Pickup Feed Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1212) and the Pickup Feed Driver PCB (UN4/ J1486) - Pickup Feed Driver PCB (UN4) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 263-1130-05

Description: Power supply error
Causes: The 12 V supply to the Drum Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1225) and the Drum Driver PCB (UN6/J1901) - Drum Driver PCB (UN6) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 263-1131-05

Description: Power supply error
Causes: The 12 V supply to the Multi-purpose Tray Pickup Driver PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the Drum Driver PCB (UN6/J1902) and the Multi-purpose Tray Pickup Driver PCB (UN97/J1351) - Multi-purpose Tray Pickup Driver PCB (UN97) - Drum Driver PCB (UN6) [Remedy] Check/replace the related harness/cable, connector and parts.

Code: 263-1150-05

Description: Power supply error
Causes: The 12 V supply to the Developing Assembly Control PCB was not detected.
Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN2/J1252) and the Developing Assembly Control PCB (UN96/J1308) - Developing Assembly Control PCB (UN96) - DC Controller PCB (UN2) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES

Code: 263-1151-05

Description: Power supply error
Causes: The 6.8 V supply to the Toner Density Sensor was not detected.
Remedy: [Related parts] R1.00 - Harness connecting from the Developing Assembly Control PCB (UN96/J1305) to the Toner Density Sensor (Y and M) (TS2/J8944 and TS3/J9014) - Harness connecting from the Developing Assembly Control PCB (UN96/J1309) to the Toner Density Sensor (C and Bk) (TS4/J9015 and TS1/J9016) - Toner Density Sensor (Y, M, C and Bk) (TS2, TS3, TS4 and TS1) - Developing Assembly Control PCB (UN96) [Remedy] Check/replace the related harness/cable, connector and parts.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie